Cross Technologies 2016-1522 Скачать руководство пользователя страница 3

Model 2016-1522#  Downconverter,  1.544 or 2.226 GHz to 70 ± 5 MHz

1.0  General

1.1  Equipment Description
The 2016-1522# Downconverter converts 1.544 or 2.226 GHz to 70 MHz. The gain is 0 to +50 dB, adjustable 
in 1±1 dB steps. Push button switches select the input frequency, gain, and other parameters. Front panel LEDs 
provide indication of DC power (green), PLL alarm (red), and Remote operation (yellow). Gain is adjustable 
manually (MGC) over a 0 to 50 dB range. Remote operation allows selection of frequency and gain. Parameter 
selection and frequency and gain settings appear on the LCD display. Connectors are Type N female for the IF 
out and RF in and BNC female for the external 10 MHz reference input (Option E) which includes a 10 MHz 
output connector which contains either the internal or external 10 MHz reference signal. The unit is powered by 
a 100-240 ± 10% VAC power supply, and housed in a 1 3/4” X 19” X 16” rack mount chassis.

MENU

EXECUTE

MODEL 2016

C

ROSS 

T

ECHNOLOGIES INC.

F=1544  G=25
ATTEN=10 REF=AUTO-I

REMOTE

ALARM POWER

DOWNCONVERTER

FRONT PANEL

AC

GND

J3

J10

J18

J2

RF IN

10 MHZ REF

10 MHZ

AND

MONITOR

EXT REF

CONTROL

OUTPUT

INPUT

J20

1

2

3

4

6

7

8

9

J1

IF OUT

REAR PANEL (Optional Ethernet Shown)

FIGURE 1.1   Model 2016-1522#  Front and Rear Panels

70 ±5 

MHz 
OUT

RF IN

   1.544  

and 

2.226 

GHz 

1750 MHz 

BP

 2870

MHz

3.294 
or 
3.976 
GHz

1.5 to 2 .3 

GHz HP/LP

70 ±5 MHz 

BP

CONTROLLER

2016-1522# Downconverter Block Diagram

VAR 

ATT

EXT
10 M

INT/EXT*
10 M

M&C

* OPTIONAL

FIGURE 1.2    Model 2016-1522#  Downconverter Block Diagram

2016-1522#  Manual, Rev. 0

                         Page 3

    

                                             06/19/17

Содержание 2016-1522

Страница 1: ...Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to includ...

Страница 2: ...riod of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entir...

Страница 3: ...z reference input Option E which includes a 10 MHz output connector which contains either the internal or external 10 MHz reference signal The unit is powered by a 100 240 10 VAC power supply and hous...

Страница 4: ...MHz 100kHz 10kHz 1kHz 100Hz Standard dBC Hz Phase Noise F Hz Controls Indicators Frequency Gain Selection Direct readout LCD manual or remote selection Power Alarm Remote Green LED Red LED Yellow LED...

Страница 5: ...emale DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts RS 232C 422...

Страница 6: ...1 for internal 10 MHz 2 for external 10 MHz Get Reference Insertion Status aaSL returns aaSLx option E only where x 0 for non insertion 1 for insertion Get Output Attenuation aaSN returns aaSNxx opti...

Страница 7: ...two character aa 00 31 prefix in the table below should be used ONLY when RS 485 OPTION Q is selected Table 1 2 2016 1522 Comma ands Commands Table 1 2 2016 1522 Commands Command Syntax Description Se...

Страница 8: ...ation of the equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and...

Страница 9: ...by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2016 1522 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 201...

Страница 10: ...external reference input 3 3 dBm 75 BNC female connector J1 IF OUT 20 to 0 MHz output 70 5 MHz dBm see Table 2 2 J2 RF IN FIGURE 2 2 2016 1522 Rear Panel I Os TABLE 2 1 J1 10 2 1 J10 Pinouts RS 232C P...

Страница 11: ...nconverter alarm DS6 POWER LED Green LED indicates presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu item...

Страница 12: ...2 3 7 Option L only To insert LNB 24 VDC on the RF center pin install 0 5A fast blo fuse in F1 and check that DS8 lights yellow Figure 2 1 8 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T...

Страница 13: ...n E Menu 6 Set Remote mode option Q Menu 7 Set RS 485 address option Q Menu 8 View LNB Current option L Save Menu When go to end Alarm indications appear on the LEDs see figure 2 3 All program changes...

Страница 14: ...erator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switc...

Страница 15: ...enu options The following display is for changing the downconverter frequency F 1554 R Pressing the Up Down switch down will toggle the display to F 2226 R NOTE CHANGES DO NOT TAKE PLACE ON FREQUENCY...

Страница 16: ...g on the cursor location G 20 R By using the horizontal rocker switch the cursor can be moved left or right Pressing the Up Down switch will toggle the display digit selected until you have the desire...

Страница 17: ...External 10 MHz signal does not meet the unit s specified parameters then the unit will not function properly The External Reference is present on the Reference Output connector J18 Auto Mode The uni...

Страница 18: ...Reference option E Menu 5 Select 10MHz Reference Out option E Menu 6 Set Remote Mode option Q Menu 7 Set RS 485 Address option Q Menu 8 View LNB current option L Save When R is selected or at the end...

Страница 19: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2016 1522 Manual Rev...

Отзывы: