2.2 Rear Panel Input/Output Signals
Figure 2.2 shows the input and output connectors on the rear panel.
AC
GND
J3
J10
J18
J1
IF OUT
10 MHZ REF
10 MHZ
AND
MONITOR
EXT REF
CONTROL
OUTPUT
INPUT
J20
1
5
2
3
4
6
7
8
9
AC1 - POWER IN
AC input for switching power
supply. 100-240 ±10% VAC,
47-60 Hz.
J2 - RF IN
-50 to -20 dBm input
1.544 & 2.226 GHz
see Table 2.2.
J10 - MONITOR AND CONTROL
DB9 female connector
see Table 2.1
J20 - Ethernet Connection
RJ45 Ethernet Connector
J18 - 10 MHz REF OUTPUT (option -E)
10 MHz external reference output
3 ± 3 dBm, 75
Ω
, BNC female connector.
J3 - 10 MHz EXT REF INPUT (Option -E)
10 MHz external reference input
3 ± 3 dBm, 75
Ω
, BNC female connector.
J1 - IF OUT
-20 to 0 MHz output
70 ±5 MHz dBm
see Table 2.2.
J2
RF IN
FIGURE 2.2 2016-1522# Rear Panel I/Os
TABLE 2.1 J1
10
2.1 J
10 Pinouts (RS-232C*)
Pin
Function
1
Not Used
2
Rx+ (RS-232C)
3
Tx+ (RS-232C)
4
Not Used
5
GND
6
Alarm Relay: Common
7
Alarm Relay: Normally Closed
8
Not Used
9
Alarm Relay: Normally Open
*Remote Serial Interface
Interface: DB-9 Male
Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit
TABLE 2.2 IFF/RF
2.2 I
F/RF Connector Options
Options
Option
IF
RF
STD
BNC, 75
Ω
Type F, 75
Ω
B
BNC, 75
Ω
BNC, 75
Ω
C
BNC, 75
Ω
BNC, 50
Ω
D
BNC, 50
Ω
BNC, 50
Ω
F
Type F, 75
Ω
Type F, 75
Ω
FN
Type F, 75
Ω
Type N, 50
Ω
J
BNC, 50
Ω
Type F, 75
Ω
K
BNC, 50
Ω
BNC, 75
Ω
M
BNC, 50
Ω
Type N, 50
Ω
N
BNC, 75
Ω
Type N, 50
Ω
S
BNC, 50
Ω
SMA, 50
Ω
2016-1522# Manual, Rev. 0
Page 10
06/19/17