Cross Technologies 2016-1522 Скачать руководство пользователя страница 1

  Instruction Manual   

               

Model 2016-1522#

Downconverter

June 2017,   Rev A

MENU

EXECUTE

MODEL 2016

C

ROSS 

T

ECHNOLOGIES INC.

F=1544  G=25
ATTEN=10 REF=AUTO-I

REMOTE

ALARM POWER

DOWNCONVERTER

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, 
equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 2016-1522

Страница 1: ...Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to includ...

Страница 2: ...riod of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entir...

Страница 3: ...z reference input Option E which includes a 10 MHz output connector which contains either the internal or external 10 MHz reference signal The unit is powered by a 100 240 10 VAC power supply and hous...

Страница 4: ...MHz 100kHz 10kHz 1kHz 100Hz Standard dBC Hz Phase Noise F Hz Controls Indicators Frequency Gain Selection Direct readout LCD manual or remote selection Power Alarm Remote Green LED Red LED Yellow LED...

Страница 5: ...emale DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts RS 232C 422...

Страница 6: ...1 for internal 10 MHz 2 for external 10 MHz Get Reference Insertion Status aaSL returns aaSLx option E only where x 0 for non insertion 1 for insertion Get Output Attenuation aaSN returns aaSNxx opti...

Страница 7: ...two character aa 00 31 prefix in the table below should be used ONLY when RS 485 OPTION Q is selected Table 1 2 2016 1522 Comma ands Commands Table 1 2 2016 1522 Commands Command Syntax Description Se...

Страница 8: ...ation of the equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and...

Страница 9: ...by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2016 1522 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 201...

Страница 10: ...external reference input 3 3 dBm 75 BNC female connector J1 IF OUT 20 to 0 MHz output 70 5 MHz dBm see Table 2 2 J2 RF IN FIGURE 2 2 2016 1522 Rear Panel I Os TABLE 2 1 J1 10 2 1 J10 Pinouts RS 232C P...

Страница 11: ...nconverter alarm DS6 POWER LED Green LED indicates presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu item...

Страница 12: ...2 3 7 Option L only To insert LNB 24 VDC on the RF center pin install 0 5A fast blo fuse in F1 and check that DS8 lights yellow Figure 2 1 8 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T...

Страница 13: ...n E Menu 6 Set Remote mode option Q Menu 7 Set RS 485 address option Q Menu 8 View LNB Current option L Save Menu When go to end Alarm indications appear on the LEDs see figure 2 3 All program changes...

Страница 14: ...erator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switc...

Страница 15: ...enu options The following display is for changing the downconverter frequency F 1554 R Pressing the Up Down switch down will toggle the display to F 2226 R NOTE CHANGES DO NOT TAKE PLACE ON FREQUENCY...

Страница 16: ...g on the cursor location G 20 R By using the horizontal rocker switch the cursor can be moved left or right Pressing the Up Down switch will toggle the display digit selected until you have the desire...

Страница 17: ...External 10 MHz signal does not meet the unit s specified parameters then the unit will not function properly The External Reference is present on the Reference Output connector J18 Auto Mode The uni...

Страница 18: ...Reference option E Menu 5 Select 10MHz Reference Out option E Menu 6 Set Remote Mode option Q Menu 7 Set RS 485 Address option Q Menu 8 View LNB current option L Save When R is selected or at the end...

Страница 19: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2016 1522 Manual Rev...

Отзывы: