Cross Technologies 2009-2425-1750 Скачать руководство пользователя страница 4

1.2   Technical Characteristics

TABLE 1.1   Model 2009-59  Equipment Specifications*

Input Characteristics

Impedance/Return Loss

50 

Ω

/12 db

         

Frequency   

2.40 - 2.50 GHz

Level

-40 to -20 dBm

Output Characteristics

Impedance/Return Loss

75 

Ω

/12 db

Frequency 

1700 - 1800 MHz

Level

-30 to -10 dBm

Output 1 dB compression

0 dBm

Channel Characteristics
 

Gain at band center

+10 dB ±2 dB

  

Spurious Response

< -40 dBC, 1700 - 1800 MHz 

Spectrum Sense

Non-inverting

  

Frequency Response

±2 dB, 1700 - 1800 MHz; ±0.5 dB, any 10 MHz increment

Synthesizer Characteristics 

LO Frequency

0.700 GHz

Frequency Accuracy

± 1.0 ppm maximum

-110

-100

-85

-75

-60

1MHz

100kHz

10kHz

1kHz

100 Hz 

                       dBC/Hz

    Phase Noise @ Freq

Indicators
  

DC Power

Green LED 

  

Alarm

Red LED 

Other 

RF Connector

Type N  (female), 50 

Ω

IF Connector

Type F (female)

Size, Bench Top

4.7” wide X 1.75” high X 6.5” deep.

Size, Rack Mount (-R)

19-inch Standard Chassis, 1.75” high x 7.0” deep (optional).

Power

+15 to +18 VDC, 250 ma on RF Out, 
Wall mount power supply unit optional)

Options 

-M

Type N RF, 50

Ω

-P4

100-240 ±10% VAC Wall Power Supply, +15 VDC

-R

1RU Rack Mounting.

-C

Power Supply not included. Requires Cross 2000-01 Power Supply.

                                                                                                                                                                            

*+10˚C to +40˚C; 2000 meters max elevation; 80% max humidity; Specifications subject to change without notice.

 

2009-2425-1750 Manual, Rev. 0

 

            Page 4

    

 

         09/05/19

Содержание 2009-2425-1750

Страница 1: ...but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be su...

Страница 2: ...oss Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not...

Страница 3: ...nominal gain of 10 dB Connectors are 75 type F female for the 1700 1800 MHz output and 50 type N female for the RF input Front panel LEDs light when DC power is applied green and when a PLL alarm occ...

Страница 4: ...requency 0 700 GHz Frequency Accuracy 1 0 ppm maximum 110 100 85 75 60 1MHz 100kHz 10kHz 1kHz 100 Hz dBC Hz Phase Noise Freq Indicators DC Power Green LED Alarm Red LED Other RF Connector Type N femal...

Страница 5: ...N FRONT SCREWS 4EA FRONT PANEL RACK MOUNT PANEL FOR R MODELS ONLY CROSS TECHNOLOGIES INC 2009 TEST DOWNCONVERTER DC ALARM REAR SCREWS 4EA REAR PANEL FIGURE 2 1 Model 2009 2425 1750 Assembly R option s...

Страница 6: ...er when installing or removing the PCB from the extrusion 2 Remove four 4 rear panel screws see Figure 2 1 3 Gently pull the rear panel and PCB assembly completely out of the extrusion 4 To install th...

Страница 7: ...promised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of...

Страница 8: ...NC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2009 2425 1750 Manual R...

Отзывы: