Model 2009-2425-1750 Downconverter

2.40 - 2.50 GHz to 1700 - 1800 MHz

1.0  General

1.1  Equipment Description 

The 2009-2425-1750 Downconverter converts a 2.40 - 2.50 GHz signal to 1700 - 1800 MHz 

with a low side local oscillator (LO) (non-inverted spectrum). Featuring low phase noise and 

high stability, this unit down converts 2.40 - 2.50 GHz signals to 1700 - 1800 MHz. The 2.40 - 

2.50 GHz input is mixed with a synthesized local oscillator (LO) signal to 1700 - 1800 MHz. 

The mixer output is applied to the output amplifier providing a nominal gain of +10 dB. 

Connectors are 75

Ω

 type-F (female) for the 1700 - 1800 MHz output and 50

Ω

 type-N (female) 

for the RF input.  Front panel LEDs light when DC power is applied (green) and when a PLL 

alarm occurs (red). DC power is provided by the LNB voltage from the receiver under test or by 

an external wall mount power supply (option -P4).  The 2009 can be mounted on an 1 3/4” X 

19” rack mount panel (option -R)

2009 TEST DOWNCONVERTER

C

ROSS 

T

ECHNOLOGIES, INC.

DC ALARM

J1

J2

J3

RF IN

IF OUT

DC POWER

C

ROSS 

T

ECHNOLOGIES, INC.

FIGURE 1.1    Front and Rear Panels

1700

to

1800

MHz
OUT

2.40

to

2.50
GHz

IN 

0.700 GHz

PLL

2009-2425-1750 Block Diagram

1.75 G

BP

2.45 G

BP

FIGURE 1.2    Block Diagram

2009-2425-1750 Manual, Rev. 0

 

            Page 3

    

 

         09/05/19

Содержание 2009-2425-1750

Страница 1: ...but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be su...

Страница 2: ...oss Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not...

Страница 3: ...nominal gain of 10 dB Connectors are 75 type F female for the 1700 1800 MHz output and 50 type N female for the RF input Front panel LEDs light when DC power is applied green and when a PLL alarm occ...

Страница 4: ...requency 0 700 GHz Frequency Accuracy 1 0 ppm maximum 110 100 85 75 60 1MHz 100kHz 10kHz 1kHz 100 Hz dBC Hz Phase Noise Freq Indicators DC Power Green LED Alarm Red LED Other RF Connector Type N femal...

Страница 5: ...N FRONT SCREWS 4EA FRONT PANEL RACK MOUNT PANEL FOR R MODELS ONLY CROSS TECHNOLOGIES INC 2009 TEST DOWNCONVERTER DC ALARM REAR SCREWS 4EA REAR PANEL FIGURE 2 1 Model 2009 2425 1750 Assembly R option s...

Страница 6: ...er when installing or removing the PCB from the extrusion 2 Remove four 4 rear panel screws see Figure 2 1 3 Gently pull the rear panel and PCB assembly completely out of the extrusion 4 To install th...

Страница 7: ...promised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of...

Страница 8: ...NC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2009 2425 1750 Manual R...

Отзывы: