background image

Instruction Manual

                   

Model 2000-02  

    Power Supply  

January 2010,   Rev. C   

2000 POWER SUPPLY

C

ROSS 

T

ECHNOLOGIES, INC.

POWER

C

ROSS 

T

ECHNOLOGIES, INC.

 IF

GND

CAUTION - RISK OF ELECTRICAL 
SHOCK  - DO NOT OPEN!!!

V2

V1

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 2000-02

Страница 1: ...ologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure t...

Страница 2: ...nologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liabl...

Страница 3: ...CTRICAL SHOCK DO NOT OPEN V2 V1 FIGURE 1 1 Model 2000 02 Front and Rear Views 1 2 Technical Characteristics TABLE 1 1 2000 02 Power Supply Specifications AC Input Characteristics Voltage 100 240 10 VA...

Страница 4: ...1 3 4 X 19 panel that can be mounted to a rack using the 4 holes at the ends See Figure 2 1 EXTRUSION FRONT SCREWS 4EA FRONT PANEL RACK MOUNT PANEL FOR R MODELS ONLY REAR SCREWS 4EA REAR 2000 POWER SU...

Страница 5: ...and outputs CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN V1 CROSS TECHNOLOGIES INC J1 AC INPUT The100 240 10 VAC 47 63 HZ input The fuse is in the tray below this and is a 2 0 amp fuse There is also...

Страница 6: ...2 Gently pull the power supply assembly completely out of the extrusion 3 With AC Power disconnected replace fuse with a 2 0 amp fuse Figure 2 4 4 Gently push the power supply assembly completely in...

Страница 7: ...Panel Fuse Box 1 Remove the 100 240 10 VAC 47 63 Hz AC power from the 2000 02 2 Pull out the fuse box below the AC Input connector Figure 2 3 3 Pry out the fuse in the back slot and measure it to see...

Страница 8: ...ing Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropria...

Страница 9: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2000 02 Manual Rev C...

Отзывы: