1. Description 

2. Safety 

Information 

3. Operating 

Instructions 

4. 

Transport, Storage, Installation 

5. Electrical 

Installation 

6. 

Power-Up, Shut-Down, Maintenance 

7. Malfunction 

8. Enclosure 

1. Description 

The Elektroblock EBL 263-5 is an energy management system for motor homes. It is a combination of 
a battery charger, a 12V distribution box and a control and switch panel. 

It contains the charging module LA 204, a battery monitor, the complete 12V distribution, fuse-protected 
12V circuits and additional control and monitoring devices. 

The controls and switches on the front panel, control the living-area functions of the motor home and 
indicate certain values like voltages or filling levels. 

Tank sensors are necessary to measure the filling levels of the water tanks. Please do order separately. 

Note: The EBL 263-5 is not suitable for filling level measurement of metal water tanks. 

1.1 Suitable 

Accessories 

rod tank sensors

 

2 rod tank sensors, 2 sensor cables 4 x 0.5 
2 seal rings art no 126.007, 2 check nuts art no 102.106

 

or tank sensors

 

8 tank sensors, art no 933.662, 2 sensor cables 4 x 0.5 

1.2 Technical 

Data 

1.2.1 General 

Data 

sizes

 

front panel:   290 x 155  
cabinet:  

275 x 130 x 173 (W x H x D in mm) 

weight 4.4 

kg 

cabinet

 

PA (Polyamide), Gentian blue RAL 5010

 

front panel

 

aluminium, powder painted, white aluminium RAL 9006 

1.2.2 Electrical 

Data 

mains supply 

*  230V (+ 6 / - 10%), 50Hz, safety class 1 

current draw 

*  230VA 

suitable batteries 

*  6 cell lead-acid or lead-gel batteries, from 35Ah  

quiescent current 

*  max 0.6mA  

off living-area battery 

load current of alternator's  *  approx 0.3A  
D+ output by EBL 

permissible load on 

*  maximum current draw up to the fuse rating of each output; 

12V outputs 

see enclosed block diagram. 

Содержание 911.056

Страница 1: ...ol the living area functions of the motor home and indicate certain values like voltages or filling levels Tank sensors are necessary to measure the filling levels of the water tanks Please do order separately Note The EBL 263 5 is not suitable for filling level measurement of metal water tanks 1 1 Suitable Accessories rod tank sensors 2 rod tank sensors 2 sensor cables 4 x 0 5 2 seal rings art no...

Страница 2: ...charge at constant 14 4V selectable 20 minutes duration for lead acid 6h duration for lead gel batteries U then automatic change over to float charge at 13 8V If due to high loads the float voltage of 13 8V cannot be provided the battery charger switches over from float to boost charge safety circuits short circuit and reverse polarity protected charger needs a connected battery with a voltage of ...

Страница 3: ...d must be conform to specifications mentioned in this operating instruction manual see instruction manual section 4 2 Installation section 5 Electrical Installation and in enclosure schematic diagram of EBL 263 5 In the following text special notice should be paid to the signs shown below Caution Electrical current hazard warning Caution General hazard warning 3 Operating Instructions 3 1 Controls...

Страница 4: ... hours Low charging current or 12V system overloaded green 12 3V Battery properly charged Standard charge Standard charge Low voltage warning indicator Optical warning of a alarming low living area battery charge As soon as the living area battery voltage drops below 10 8V the red warning light starts blinking Any load must now be switched off immediately and the living area battery should be rech...

Страница 5: ...s shown Actuate switch in direction of Filling level of waste water tank is shown LED with symbol is on water tank full LED with symbol is on water tank approx half full LED with symbol is on water tank approx a quarter full No LED indication water tank empty Note Inquiry of water tank filling levels is for temporary use only The used method of measurement is not suitable for continuous operation ...

Страница 6: ...ws at each corner of the front panel and pull out the device Disconnect all positive poles of each of the seven consumer circuits label each one well Insert a new main fuse Caution danger of burning Better disconnect the positive battery terminal first If the fuse blows again the main circuit of the battery is at fault otherwise Actuate 12V switch on front panel of EBL 263 5 the green LED must lig...

Страница 7: ...rt period of time However the 12 V system cannot be switched on if the battery voltage stays under 11 0V In any case the living area battery should be fully recharged as soon as possible 4 Transport Storage Installation 4 1 Transport Storage The EBL should be stored and transported in a suitable packing and in a dry environment only Storage temperature range 20 C to 70 C 4 2 Installation The EBL h...

Страница 8: ...act junction box The device must be used exclusively in vehicles equipped with an easily accessible cut out eg a circuit breaker in the wardrobe 5 2 Batteries and D Alternator The battery is connected by a 3 pole EURO terminal The alternator control signal D is connected to terminal 6 of the 6 pole plug in screw terminal water tank 2 waste water Cable size dimensions have to be in accordance with ...

Страница 9: ...type selector switch See section 3 1 Controls 6 2 Shut Down Before and after shut down eg winter recess the battery should be fully recharged Connect the motor home to mains supply and charge the battery for a minimum of 16 hours 80Ah battery or 24 hours 160Ah battery Before long periods of disuse the motor home battery should be disconnected from the 12V system Take off terminals at battery poles...

Страница 10: ...ore not liable to resulting damages 8 Enclosure To this operating instruction manual belongs the enclosed schematic diagram the table of measurement and front and back view drawings of the Elektroblock EBL 263 5 art no 911 056 This operating instruction manual with all its enclosures must be delivered together with the energy management system Elektroblock EBL 263 5 art no 911 056 It has to be par...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Отзывы: