2.2  Indicators The following are the front panel indicators. There are no controls to adjust.

PS 1

PS 2

ACTIVITY

ALARM

1 : 8

DUAL  1 : 4

RS-422

RS-423

MODE

POWER

A    B

A    B

C

ROSS 

T

ECHNOLOGIES INC.

MODEL 1583

DATA DISTRIBUTION

AMPLIFIER

FIGURE 2.4 1583-10 FRONT PANEL INDICATORS

TABLE 2.3   FRONT PANEL INDICATORS

 

  Description

 ITEM

  

Illuminates green when DATA B’s interface is set to RS-423 and the selected 

  mode is 2:4.  DATA B’s interface is selected with a switch located on the 
  rear panel and shown in Figure 2.1.

 RS-423 B:

  

Illuminates green when DATA B’s interface is set to RS-422 and the selected 

  mode is 2:4.  DATA B’s interface is selected with a switch located on the rear
  panel and shown in Figure 2.1.

 RS-422 B:

  

Illuminates green when DATA A’s interface is set to RS-423.  DATA A’s interface is

  selected with a switch located on the rear panel and shown in Fig.2.1.

 RS-423 A:

  

Illuminates green when DATA A’s interface is set to RS-422.  DATA A’s interface is

  selected with a switch located on the rear panel and shown in Fig.2.1.

 RS-422 A:

  

Illuminates green when the selected mode is 2:4.  The mode is selected with the

  MODE switch located on the rear panel and shown in Figure 2.1.

 MODE 2:4

  

Illuminates green when the selected mode is 1:8.  The mode is selected with the

  MODE switch located on the rear panel and shown in Figure 2.1.

 MODE 1:8

  

Illuminates red when no data activity is detected from DATA IN B (J2) for a time

  period of 1 minute and the selected mode is 2:4.  Other time periods can be  
  programmed at the factory by contacting Cross Technologies.
  ([email protected])

 ALARM B:

  

Illuminates green when data activity is detected from DATA IN B (J2) and the

  selected mode is 2:4.

 ACTIVITY B:

  

Illuminates red when no data is detected from DATA IN A (J1) for a time period of  

  1 minute.  Other time periods can be programmed at the factory by contacting  
  Cross Technologies. ([email protected])

 ALARM A:

  

Illuminates green when data activity is detected from DATA IN A (J1).

 ACTIVITY A:

  

Illuminates green when power is applied to AC 2 input on the rear panel

  

Illuminates green when power is applied to AC 1 input on the rear panel

 POWER CH2 LED:

 POWER CH1 LED:

1583-10 Manual, Rev. A 

 

 Page 6

 

    06/10/10

Содержание 1583-10

Страница 1: ...ross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll...

Страница 2: ...igation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shipping costs for warranty re...

Страница 3: ...ount chassis Rear panel provides Alarm Interface DB25 and Data type selection RS 422 or 223 RS232 compatible switches CROSS TECHNOLOGIES INC PS 1 MODEL 1583 DATA DISTRIBUTION AMPLIFIER PS 2 ACTIVITY ALARM 1 8 DUAL 1 4 RS 422 RS 423 MODE POWER A B A B 1583 10 FRONT PANEL 1 1 Technical Specifications Data Characteristics Input Output RS422 423 RS232 compatible Data rate 512 kB s max Inputs Outputs 1...

Страница 4: ...witch In the 1 8 mode the data out A B J8 J9 J10 J11 signals are also set with this switch DATA B INTERFACE Selects the interface for CH B if the selected mode is 2 4 Both the data in J2 and data out J8 J9 J10 J11 signals are set with this switch This switch has no affect if the selected mode is 1 8 FIGURE 2 1 1583 10 REAR PANEL TABLE 2 0 INPUT OUTPUT CONNECTORS Data Input J1 J2 Data Connectors Fi...

Страница 5: ... 4 Normally Closed 13 Mode Status 2 4 Normally Open 12 Alarm B Common 11 Alarm B Normally Closed 24 Alarm B Normally Open 23 Alarm A Common 22 Alarm A Normally Closed 10 Alarm A Normally Open 9 Power Supply 2 Status Common 8 Power Supply 2 Status Normally Closed 21 Power Supply 2 Status Normally Open 20 Power Supply 1 Status Common Power Supply 1 Status Normally Closed Power Supply 1 Status Normal...

Страница 6: ...r panel and shown in Fig 2 1 RS 422 A Illuminates green when the selected mode is 2 4 The mode is selected with the MODE switch located on the rear panel and shown in Figure 2 1 MODE 2 4 Illuminates green when the selected mode is 1 8 The mode is selected with the MODE switch located on the rear panel and shown in Figure 2 1 MODE 1 8 Illuminates red when no data activity is detected from DATA IN B...

Страница 7: ...t protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connection to the Branch use of power strips Top Cover There are no serviceable parts inside the product so ...

Страница 8: ...low blow AC Fuse Drawer FUSE DRAWER SPARE FUSE DRAWER AC Fuse 2 amp slow blow Type T 5 mm X 20 mm INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 240 V 1583 10 Manual Rev A Page 8 06 10 10 ...

Страница 9: ... INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2010 Printed in USA 1583 10 Manual Rev A Page 9 06 10 10 ...

Отзывы: