2.0  Installation

2.1  Input/Output Connectors and Switches

The following are the input and output connectors.

POWER IN 1

J4-DATA  

 POWER IN 2

AC1

100-240VAC 47-63 Mz

    

AC 2

GND

J4

J5

J3

J6

J7

Data OUT A   

J8

J9

J10

J11

DATA A

422/423

MODE

1:8 / 2:4

DATA B

422/423

Data OUT A/B       

ALARM INTERFACE    

DATA IN A    

LOOP DATA OUT  A/

DATA IN B             

J1

J2

J6-DATA  

FAC1

FAC2

J5-DATA  

J7-DATA  

422/423

(RS232C Compatible)  

MODE SWITCH
Selects the unit

s

operating mode 
to 1:8 or 2:4.

J8-DATA  

J10-DATA  

J9-DATA  

J11-DATA  

DATA A INTERFACE

Selects the interface for CH A. Both the data 

in (J1) and data out (J4, J5, J6, J7) signals 

are set with this switch. In the 1:8 mode, the 

data out A/B (J8, J9, J10, J11) signals are 

also set with this switch.

DATA B INTERFACE
Selects the interface for CH B if the selected 
mode is 2:4. Both the data in (J2) and data out 
(J8, J9, J10, J11) signals are set with this 
switch. This switch has no affect if the selected 
mode is 1:8.

FIGURE 2.1   1583-10 REAR PANEL 

TABLE 2.0   INPUT / OUTPUT CONNECTORS

Data Input: J1, J2, - Data Connectors  (Figure 2.1)
Data Output: J4, J5, J6,J7, J8, J9, J10, J11 -  Data Connectors  (Figure 2.1)

Function

Pin Number

Description

DATA

2

RS-423

 2, 

7

RS-422

GROUND

5

Ground

NO CONNECTION

1, 3, 4, 6, 8

No Connection

5

4

3

2

1

9

8

7

6

FIGURE 2.2   DB9 PIN OUT

AC1, AC2 - POWER IN - Provides AC inputs for dual power supply.

FAC1, FAC2 - 2 AMP FUSES - 2 AMP slow blow 115 VAC fuses for the dual power supplies.

1583-10 Manual, Rev. A 

 

 Page 4

 

    06/10/10

Содержание 1583-10

Страница 1: ...ross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll...

Страница 2: ...igation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shipping costs for warranty re...

Страница 3: ...ount chassis Rear panel provides Alarm Interface DB25 and Data type selection RS 422 or 223 RS232 compatible switches CROSS TECHNOLOGIES INC PS 1 MODEL 1583 DATA DISTRIBUTION AMPLIFIER PS 2 ACTIVITY ALARM 1 8 DUAL 1 4 RS 422 RS 423 MODE POWER A B A B 1583 10 FRONT PANEL 1 1 Technical Specifications Data Characteristics Input Output RS422 423 RS232 compatible Data rate 512 kB s max Inputs Outputs 1...

Страница 4: ...witch In the 1 8 mode the data out A B J8 J9 J10 J11 signals are also set with this switch DATA B INTERFACE Selects the interface for CH B if the selected mode is 2 4 Both the data in J2 and data out J8 J9 J10 J11 signals are set with this switch This switch has no affect if the selected mode is 1 8 FIGURE 2 1 1583 10 REAR PANEL TABLE 2 0 INPUT OUTPUT CONNECTORS Data Input J1 J2 Data Connectors Fi...

Страница 5: ... 4 Normally Closed 13 Mode Status 2 4 Normally Open 12 Alarm B Common 11 Alarm B Normally Closed 24 Alarm B Normally Open 23 Alarm A Common 22 Alarm A Normally Closed 10 Alarm A Normally Open 9 Power Supply 2 Status Common 8 Power Supply 2 Status Normally Closed 21 Power Supply 2 Status Normally Open 20 Power Supply 1 Status Common Power Supply 1 Status Normally Closed Power Supply 1 Status Normal...

Страница 6: ...r panel and shown in Fig 2 1 RS 422 A Illuminates green when the selected mode is 2 4 The mode is selected with the MODE switch located on the rear panel and shown in Figure 2 1 MODE 2 4 Illuminates green when the selected mode is 1 8 The mode is selected with the MODE switch located on the rear panel and shown in Figure 2 1 MODE 1 8 Illuminates red when no data activity is detected from DATA IN B...

Страница 7: ...t protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connection to the Branch use of power strips Top Cover There are no serviceable parts inside the product so ...

Страница 8: ...low blow AC Fuse Drawer FUSE DRAWER SPARE FUSE DRAWER AC Fuse 2 amp slow blow Type T 5 mm X 20 mm INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 240 V 1583 10 Manual Rev A Page 8 06 10 10 ...

Страница 9: ... INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2010 Printed in USA 1583 10 Manual Rev A Page 9 06 10 10 ...

Отзывы: