MODEL 1582-03 Data Switch

1.0  General

1.1  Equipment Description 

The 1582-03 Data Switch provides Auto, Manual, or Remote relay switching between CH1 and CH2 RS232C 

data signals on pins 2 or 3, selectable, with pin 5 ground and the other pins of the DB9 connectors not 

connected. Alarm conditions are either if data is lost for a preset 1 to 9 minutes on CH1, CH2 or with external 

alarm contact closures. The 1582-04 has  two switches in one chassis. Switching logic can be jumper selected 

as follows:

1. CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back 

when CH1 no longer in alarm or both CH1 and CH2 are bad.

2. Latch to CH2 Mode - Latches to CH2 if CH1 alarms and CH2 is good. Return to CH1 only when Manual 

Reset switch is pushed or Remote Reset pin is grounded and if no alarm on CH1.

3. Minimum AUTO switching, Initial Channel Select ( ICS) Mode - Switch stays on channel last selected 

by Manual or Remote selection after return to AUTO. AUTO switching occurs only  if current channel 

alarms and other channel is clear.

If power is lost or first applied (as alarms at power up dictate), CH1 is selected. The Manual Select switch and 

(when in AUTO) contact closures to Remote Select pins, select CH1 or CH2 independent of alarms. LEDs and 

closures indicate alarms and switch selection of CH1 or CH2 and REMOTE or MANUAL operation. 

Redundant power supplies.

  

SWITCH A

MODEL 1582

POWER

1      2

   AUTO   

 CROSS TECHNOLOGIES, INC.

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

SWITCH B

   AUTO   

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

FRONT PANEL

AC1

AC2

DATA 2 

1

J8

GND

DATA 1

DATA OUT  

J103

J107

J106

FIGURE 1.1 Model 1582-03 Front and Rear Panels

SELECTED 
DATA 

1582-03 BLOCK 
DIAGRAM

CH 1
DATA  

CH 2 

DATA   

AUTO

CH 1 

CH 2

CONTROL LOGIC

ALM 
DET 

CH1

ALM 
DET 

CH2

MANUAL 

SELECT

  1  2
 REM.

  1   2
 ALM

 1  2  1 OR 2
 DATA ALARM

REM.

SW 
RST

  1  2
 MON

M R
A E

N M

1582-03 Manual, Rev. C

 

 

 Page 3

    

    4/13/09

Содержание 1582-03

Страница 1: ...in are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Страница 2: ...Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall no...

Страница 3: ...nel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to AUTO AUTO switching occurs only if current channel alarms and other channel is clear If power is...

Страница 4: ...h to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to AUTO Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected CH2 ON LINE Turns green when...

Страница 5: ...t connectors AC1 AC2 DATA 2 1 J8 GND DATA 1 DATA OUT J103 J107 J106 AC1 POWER IN 1 1 5 A FUSE AC2 POWER IN 2 1 5 A FUSE J106 DATA 1 J107 SWITCHED DATA J103 DATA 2 J8 CONTROLS FIGURE 2 0 1582 03 REAR P...

Страница 6: ...Remote to Auto REMOTE INDICATION 15 Open collector output 5 to gnd when in REMOTE mode MANUAL INDICATION 8 Open collector output 5 to gnd when in MANUAL mode SWITCH 1 MON 11 Relay closure to J8 pin 6...

Страница 7: ...times out or on external alarm input REMOTE LED Turns amber when REMOTE control is active MANUAL SELECT 3 position switch as follows LEFT manually select Channel 1 center Auto switch position determin...

Страница 8: ...o the connection of the equipment to the supply circuit and the effect that overloading of cicuits could have on overcurrent protection and supply wiring Appropriate consideration of equipment namepla...

Страница 9: ...2 Momentarily ground remote Reset pin 4 on J8 to return to Auto operation FUSE DRAWER SPARE FUSE DRAWER AC Fuse 2 amp slow blow Type T 2A GDC 5 mm X 20 mm INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TY...

Страница 10: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 11: ...HNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 03 Manual Rev C Page 1...

Отзывы: