5.1 

Synchronization principle 

When multiple AM systems and deactivators are installed in 

each other’s vicinity, it’s very 

important  to  properly  synchronize  the  transmission  burst  and  receiver  windows  for  all 
systems  involved.  If  systems  are  not  properly  synchronized  they  might  create  false 
alarms and poor detection! Keep in mind that AM signals, when compared to other EAS 
technologies, can “travel” quite far. 

Figure 6 shows two AM systems that are not properly synchronized. 

 

Figure 6: Two AM systems NOT synchronized 

The transmission burst of system B starts later than the burst of system A, resulting in the 
fact that system A is receiving the transmission burst of system B in its receiver window. 
This  will  create  false  alarms  and  poor  detection  on  system  A,  where  system  B  will 
function  properly  as  the  transmission  burst  of  system  A  is  not  affecting  the  receiver 
window of system B. 

This problem can be solved by making sure that both systems transmit and receive at the 
same  moment,  which  can  be  realized  by  changing  the  delay  time  for  one  of  the  two 
systems.  

Example: 

System A has currently a delay time of 0.2ms and system B a delay time of 1.4ms. The 
delay  time  of  system  B  needs  to  be  corrected  to  the  delay  time  of  system  A  (or  vice 
versa), so their mutual transmission burst and detection windows will overlap each other 
(see Figure 7). This will result in both systems working properly without interference (see 
Figure 8).  

 

Tr
a

n

s

mi
s

s

ion
 b

u

rs

R

e

c

e

iv

e

r w

ind
o

w

 

 

R

e

fe

re

n

c

e

 w

in

d

o

w

 

 

20ms 

0ms 

Tr
a

n

s

mi
s

s

io

n

 b

u

rs

R

e

c

e

iv

e

r w

ind
o

w

 

 

R

e

fe

re

n

c

e

 w

ind
o

w

 

 

System A 

System B 

50Hz mode 

Содержание NEXUS AM

Страница 1: ...Technical Manual NEXUS AM Deactivator...

Страница 2: ...chanical specifications 8 3 General AM and EAS issues 9 3 1 Noise sources 9 3 2 Installation guidelines 9 3 3 Safety instructions 10 3 3 1 Serviceable parts 10 4 Equipment and tools 11 4 1 General ins...

Страница 3: ...NEXUS AM Deactivator Terms and abbreviations v2 1 Page 3 of 26 8 FCC STATEMENT 26...

Страница 4: ...rred to as pedestal barrier Burst Frequency Fb The operating frequency of the TRX Device Explorer Device Explorer Cross Point Device Explorer Software tool for adjustment of Cross Point devices that a...

Страница 5: ...o a host e g a CrossCONNECT Access Point or a computer and communicate with this host using the Cross Point Field Bus Protocol This allows retrieval of device information and various settings to be ma...

Страница 6: ...specify your dealer code in order to be able to use the Device Explorer software If you do not have a dealer code yet then contact Cross Point to obtain one 2 2 3 Detection deactivation distances The...

Страница 7: ...Point s Field Bus network in combination with NEXUS AM anti shoplifting systems Figure 3 Field Bus structure in combination with NEXUS RF By connecting the NEXUS AM Deactivator in the NEXUS AM network...

Страница 8: ...0 x 240 x 65mm Power supply 230VAC or 115VAC 50 60Hz Current consumption 115VAC 320mA 230VAC 160mA Temperature range 0 50 o C Frequency 58kHz Technology Pulse listening Acoustic Magnetic AM Detection...

Страница 9: ...ing and revolving doors elevators escalators roller shutters frames etc Electronic devices like computers laptop screens LCD screens cash registers engines transformers etc Vertically positioned power...

Страница 10: ...0VAC default setting to 115VAC or vice versa Use switch SW1 to change the mains voltage setting b The device is not working and one of the internal fuses needs to be checked or replaced c The device i...

Страница 11: ...nts are set for the laptop Intel 1 3GHz or faster processor Microsoft Windows XP Home or Professional with Service Pack 3 32 bit or Service Pack 2 64 bit Microsoft Windows Vista with Service Pack 2 32...

Страница 12: ...l tag will be detected in the receiver window and a deactivation burst is triggered A single 50Hz mains frequency cycle is dived into three phases phase A B and C Each phase covers 1 3 of the 50Hz cyc...

Страница 13: ...ssion burst of system B in its receiver window This will create false alarms and poor detection on system A where system B will function properly as the transmission burst of system A is not affecting...

Страница 14: ...synchronization can be performed by making use of Cross Point s software The exact synchronization procedures are described in chapter 0 Transmission burst Receiver window Reference window 20ms 0ms T...

Страница 15: ...be used as input for a foot switch 3 External LEDs connector Type RJ 11 Do not connect a telephone line to this connector 4 Termination switch Used to terminate the Field Bus Must be activated when th...

Страница 16: ...ces After entering the Other devices screen the Scope view of the AM Deactivator is shown The scope view shows the threshold level red line and signal level blue line Furthermore a noise level indicat...

Страница 17: ...bled As a result of this the deactivator will not detect any labels Make sure to leave this screen to enable detection and deactivation of labels again When the transmission bursts are not synchronize...

Страница 18: ...zation button to open the underlying menu Start automatic synchronization mode 7 2 2 1 When this option is selected the software will detect the best position for the transmission burst Just click the...

Страница 19: ...onfiguration events Each event type can be distinguished by means of their individually colored icons By default all types of alarms are displayed but pressing one or more of the filter buttons will s...

Страница 20: ...d tags Click the Delete button to delete all deactivations in the list and to permanently remove them from the selected deactivator All deactivations are date time stamped so it s easy to find out whe...

Страница 21: ...tor see section xxx also the Tag detected notifications can be set Notification settings can be saved for usage in other stores Click the Load and save notifications button and select the option Save...

Страница 22: ...of the user Notification settings can be saved for usage in other stores Click the Load and save notifications button and select the option Save notifications from the menu and the Save notifications...

Страница 23: ...abels will be detected and deactivated By default the range is set to detect labels between 55kHz and 61kHz 6kHz bandwidth total In case there are many false deactivations caused by ambient noise sign...

Страница 24: ...if an infinite deactivation window is required The Number of deactivations represents the maximum number of deactivations that are allowed within the deactivation time window If the deactivation time...

Страница 25: ...put will increase the performance of the deactivator where a lower output will result in less performance The tuning is fixed and cannot be changed The graph only indicates the antenna voltage so you...

Страница 26: ...separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tec...

Отзывы: