• Use of Timeslot 16 (Timeslot 16): Use - the timeslot may be used for data transmission,
Skip - the 16-th timeslot is used to transmit CAS multiframes generated by the
multiplexing modem. This menu item is not displayed, if the port operates in
transparent G.703 stream translation mode;
• CRC4 supercycle generation and control (CRC4): Yes - CRC4 multiframe generation
and checking enabled, No - disabled. This menu item is not displayed, if the port
operates in transparent G.703 stream translation mode;
• Idle code (Idle code): an eight-bit code (0x00 - 0xff), which is transmitted in unused
timeslots. In the majority of cases, this parameter must be set to the 0xd5 value. This
menu item is not displayed, if the port operates in transparent G.703 stream translation
mode;
• Maximum receiver gain (Receiver gain): Low - low gain (12 dB), High - high gain
(43 dB);
• Reaction to the loss of synchronization (Loss of sync action): AIS - the AIS alarm
indication signal AIS (“Blue Code”) is output to the port during signal of frame
synchronization loss, Remote Alarm – bit A of the zero timeslot is set.
In order to disable the E1 port, it is required to set the framed mode (Framing: E1) and
not to assign and timeslots (from the “Timeslots” item).
Ethernet port configuration
Port 1
1. Payload Rate: 256 kbps (4x64 kbps)
4. Negotiation: Manual
5. Media Type: 100Base-T
6. Duplex: Half
7. Filtering: Enabled
Command: _
The following parameters should be set for the operation of the Ethernet port:
• Payload Rate – Ethernet port bandwidth (64 - 2304 kbit/s, N x 64 kbit/s, N = 1...36).
In order to disable the Ethernet port, it is required to specify a 0 kbit/s bandwidth;
• Negotiation – Rate and Duplex parameter setting mode: Automatic or Manual;
• Media Type – Ethernet port mode: 100Base-T or 10Base-T
(when Negotiation=Manual);
• Duplex – duplex mode: Full or Half (when Negotiation=Manual);
• Filtering – packet filtering: Enabled or Disabled.