background image

7

6

Connection to a Home Power Supply

Connections for standby power to a building’s electrical system 

must be made by a qualified electrician. The connection must 

isolate the generator power from utility power and must 

comply with all applicable laws and electrical codes. 

  WARNING

:

 Improper connection to a building’s electrical 

system can allow current from the generator to backfeed 

into the utility lines. Such backfeed may electrocute 

people who come into contact with the lines during 

the power outage, such as utility company workers. 

Furthermore, the generator may explode, burn or cause 

fires when power is restored. Consult the utility company 

or a qualified electrician prior to making any power 

connections. 

RIGHT

RIGHT

WRONG

Safety Regulations 

There are warning labels on the machine to remind you of 

safety regulations.

NEVER USE INSIDE a home 

or garage. EVEN IF doors 

and windows are open.

ONLY USE OUTDOORS 

and far away from 

windows, doors & vents.

READ THE OPERATION MANUAL BEFORE USE

Pay attention to important safety and health 

warnings and instructions.

■  Understand and follow warnings and cautions.

■ Do not operate unless guards are in place.

HIGH VOLTAGE GENERATOR

■  Do not connect to any building electrical system.

■  Do not overload generator.

■  Non-qualified people (including under-aged

  children) are not allowed to operate.

EXHAUST FUMES ARE POISONOUS

■  Do not operate in unventilated areas.

■  Carbon monoxide (CO) danger.

Using a generator indoors CAN KILL IN MINUTES. 

Generator exhaust contains carbon monoxide. 

This is a poison you cannot see or smell.

PETROL AND ITS VAPOUR ARE 

FLAMMABLE AND EXPLOSIVE

■  Keep away from heat, sparks & flame sources. 

■  DO NOT refuel when operating.
GENERATORS PRODUCE ELECTRICITY THAT 

CAN CAUSE SERIOUS INJURY OR DEATH 

■  Operate only in dry areas away from 

 moisture, rain, snow and standing water.

 CAUTION: Hot Surfaces.

   CAUTION: Read the safety 

instructions before using the 

generator.

   CAUTION: Gases such as carbon 

monoxide (colourless and odourless 

gas) are produced during operation 

which may lead to suffocation. Only 

use the generator in well-ventilated 

areas.

   CAUTION: Fuel is highly flammable 

and extremely explosive. Fire or 

explosion can cause severe burns 

or death. Keep flammable items 

away while handling fuel. Fill 

fuel tank outdoors and in a well-

ventilated area with the generator 

stopped. Always wipe off spilled 

fuel and wait until the fuel has dried 

before starting the generator. Do 

not operate the generator with 

known leaks in the fuel system. Use 

proper fuel storage and handling 

procedures. Do not store fuel or 

other flammable materials nearby. 

Empty the fuel tank before storing 

or transporting the generator. Keep 

fire extinguisher handy and be 

prepared if a fire starts.

   WARNING: Dangerous voltages 

are present when the generator is 

in operation. The generator must 

always be switched off before 

performing maintenance.

   CAUTION: Wear ear protection 

when operating the generator.

   CAUTION: Disconnect all devices 

from the connections before 

performing maintenance works, 

before leaving the device and after 

switching it off.

   WARNING: 

Modifications to any part of the generator is 

not allowed and may void your warranty.

  WARNING

: This generator is intended for residential 

consumer use only. This generator is not designed for 

permanent installation.

Содержание Cromtech 7000ie

Страница 1: ...CROMTECH 7000ie OPERATION MANUAL INVERTER GENERATOR...

Страница 2: ...claim under the warranty you must return the product with proof of purchase to the closest warranty agent or to the place of purchase Where a failure does not amount to a major failure Crommelins Mac...

Страница 3: ...lert Symbol including DANGER You WILL be KILLED or SERIOUSLY HURT if you don t follow instructions WARNING You CAN be KILLED or SERIOUSLY HURT if you don t follow instructions CAUTION You CAN be HURT...

Страница 4: ...ation Do not place flammable objects close to the exhaust when generator is operating Keep at least one metre away from flammable materials Do not use in confined spaces WARNING Do not connect to a ho...

Страница 5: ...t see or smell PETROL AND ITS VAPOUR ARE FLAMMABLE AND EXPLOSIVE Keep away from heat sparks ame sources DO NOT refuel when operating GENERATORS PRODUCE ELECTRICITY THAT CAN CAUSE SERIOUS INJURY OR DEA...

Страница 6: ...or 17 Air filter 18 Frame shock absorber bracket left 19 Left maintenance door 20 Spark plug 21 Combination switch 22 Tank cover front Control Panel Diagram 1 2 3 4 5 6 9 10 11 12 7 8 INVERTER GENERAT...

Страница 7: ...t Button to start the engine Recoil Starter When battery voltage is too low or flat use the manual recoil starter to start the engine ESC Throttle Switch ESC THROTTLE STANDARD TURBO ECO 1 2 3 ECO When...

Страница 8: ...If there is no display after replacing the battery with new one please contact your dealer b The screen interface displays the contents of 21 22 and 23 2 display interfaces in total NOTE The interfac...

Страница 9: ...the contents of 9 displayed with Bluetooth and 10 are also displayed at the same time 5 When the engine switch is in the ON position and the engine is either running or not the screen interface will...

Страница 10: ...ngine starts and produces power Ground Earth Terminal The ground terminal on this generator is connected to NON current carrying parts of the generator frame and to each AC outlet Before attaching a g...

Страница 11: ...engine in a closed area or it may cause unconsciousness and death within a short time Operate the engine in a well ventilated area The generator has been shipped without engine oil Do not start the en...

Страница 12: ...f connecting NOTE You can have multiple devices paired to the device however only one connected at a time APP START APPLE 1 On your Apple device visit the App Store 2 In the App Store search for ILONC...

Страница 13: ...electrical equipment 2 Turn the ESC Throttle to the Standard position 3 Disconnect all electrical equipment from the AC socket 4 Manual stopping press and release the start switch button on the contr...

Страница 14: ...ed appliance s will shut off and the output indicator green will go OFF Stop engine and investigate the problem Determine if the cause is a short circuit in a connected appliance or an overload correc...

Страница 15: ...l gauge 10 Rotate the lock 90 clockwise and close right maintenance door Oil Specification Table Use four stroke oil SAE 10W30 is recommended for regular use However when the average temperature in yo...

Страница 16: ...must not be broken or cracked If it is damaged it must be replaced Spark Plug NOTICE Incorrect spark plug can cause damage to the engine To replace or clean the spark plug use the spark plug spanner k...

Страница 17: ...l of the battery and tighten the installation bolt 4 Install the battery band 5 Reinstall battery maintenance cover and tighten the bolts NOTICE The generator must not run without the battery maintena...

Страница 18: ...NG TRANSPORTATION Before transportation allow the generator set to cool completely To prevent fuel spillage when transporting or during temporary storage the generator should be secured upright in its...

Страница 19: ...ut 15 ml of oil into the cylinder Turn the Engine Switch to the OFF position Crank the engine by pulling the manual recoil starter a few times to lubricate the cylinder Refit the spark plug and mainte...

Страница 20: ...Capacity 1 45 litres Spark Model No NGK BPR7ES Starting mode Recoil start Electric start APP start Generator Length x Width x Height 950x765x773 mm Wheel Solid 2 x 250mm Net weight 130kg WIRING DIAGR...