28
English
If the unit which you are connecting is the last one of the DMX line, insert a 120 Ω terminal resistor connected
between DATA- and DATA+, as shown and following.
Execute stages
“A”
and
“B”
, as previously described.
C.
Connect the 120 Ω resistor
“15”
between DATA- and DATA+
and press the butt connectors by a proper tool.
D.
Heat the tube
“16”
by using a heater for heat shrink tubes
“17”
till the complete shrinkage and then press the final end of the
tube with a pincer
“18”
in order to seal the connection.
7.1 Setting operating mode
By the control panel it is possible to select one of the following operating modes:
• using DMX512 signal control mode
Each fixture is controlled from DMX512 signal control.
(see chapter
8.0 DMX function
)
• MASTER-SLAVE or AUTOMATIC mode
The projector operates independently, without DMX512 signal control.
(see chapter
9.0 MASTER/SLAVE and AUTOMATIC function
)
• using FIXED COLOURS mode
The projector operates independently, without DMX512 signal control.
(see chapter
10.0 FIXED COLOURS function
)
The unit NORMALLY works in DMX mode and, on turning on, the display will read the number of DMX address (e.g. 012).
If on turning on the display will read “AUT”, it will mean that the unit is working in AUTOMATIC mode.
Disable this function to go back to the DMX mode.
If on turning on, the display will read “COL”, it will mean that the unit is working in FIXED COLOURS mode.
Disable this function to go back to the DMX mode.
7.0 Use of the unit
16
17
18
15
DA
TA-
DA
TA+