background image

Voltage Guard – 70 

 
 

The best solution to protect your battery 
against : 

    

Deep discharge 

 

 

Overvoltage  

 

Overload 

 

Presentation

 

The voltage guard protects your battery in order 
to increase its duration life. 
It provides a constant low voltage, overvoltage 
and overload protection. 
  
When you battery reaches the pre-set low 
voltage the voltage guard will disconnect 
automatically the DC consumers.   
DC consumers will be switched on again 
automatically when battery voltage increases and 
when defined threshold is reached.  
The system will operate the same say way for 
over-voltage. 
 
Low voltage threshold can be selected from 
external DIP switches. The over-voltage value is 
fixed. 
 
The system can be used as manual main switch. 
The output is turned off when the switch is 
closed. 
In this mode the voltage guard will only operate 
as battery low voltage protector. 
 
The voltage guard has an integrated buzzer and 
LED to monitor its operating state. 
 
It is compliant with all Lead battery types : wet, 
sealed, gel, AGM, Calcium, etc. 
 

Installation 

The voltage guard has to be installed on a solid 
surface and in a dry and well ventilated place.  
 
Never use the voltage guard where there is any 
danger of explosive gas. 
 

Connection and possible additional protections 
shall be made in compliance with local and 
concerned application regulations. 
 
Appropriate terminal shall be used to avoid bad 
connection.  
 
Fasten the bolts tightly but not over tighten 
them.  
 
Use wiring with the appropriate diameter.  
 
Make sure the battery is fused with the right 
value. This fuse can be 70A maximum, limited by 
the voltage guard.  
 
Connect the voltage guard according the wiring 
diagram as shown below.  
 

Standard : 

Connect the 

 terminal to the ground of the 

installation.  
Connect the 

 terminal to the positive pole of 

the battery.  
Connect the 

  terminal to the con 

terminal.  
 

Optional : 

Connect the

 terminal to a switch to ground to 

use main switch function. 
Connect the !    terminal to an external alarm. 
This signal switches to ground in case of a low 
battery (maximum alarm load 1A). 

Connect the 

 terminals to an external three 

colour LED if desired

www.cristec.fr 

Отзывы: