20
3.3.2
« AUTOMATIC COUPLING » devices
Automatic versions (IT2000A and IT3600A) detect input isolation transformer network and automatically switches to
the corresponding voltage configuration.
Beforehand, only outputs must be manually configured using cables provided in the accessory bag.
CAUTION
* Output Coupling must be done in accordance with the on board need. An error in the choice could cause the
destruction of the on-board pieces of equipment.
115VAC output voltage configuration :
230VAC output voltage configuration :
3.3.3
Isolation transformer Leds indicators
These Leds are visible on the casing front panel
White Led
presence of mains network
Green Led 115VAC
input coupling to 115VAC network
Green Led 230VAC
input coupling to 230VAC network
Red Led
equipment overheating (by internal transformer thermostat)
Input voltage
White Led
« Network »
Green Led
115VAC
Green Led
230VAC
System condition
0 – 70 V
ON
OFF
OFF
xx
70 – 135 V
ON
ON
OFF
115VAC input configuration
135 – 185 V
ON
OFF
OFF
xx
185 – 265 V
ON
OFF
ON
230VAC output configuration
Output
coupling