JUMPER PLUG PROGRAMMING
The jumper plugs are located on the topside of the control module behind a small access door. To change the
programmable options on this system, jumper pins must be removed or shorted. See the diagram and chart for alarm
configuration options.
JUMPER
PLUG
SIDE VIEW
JUMPER
PINS
P1 P2 P3 P4 P5 P6 P7 P8
TOP OF MODULE
OPEN
(REMOVED)
(ATTACHED)
SHORTED
REMOVE
DOOR
PIN #
SHORTED
OPEN
P1
Passive Arming
NO Passive Arming
P2
Passive Door Locks
NO Passive Locks
P3
Door-open warning 5
Sec. after armed
No Door-open
warning after armed
P4*
Autolock with Ignition NO Autolock
P5*
1 Sec. Lock/Unlock
Pulse
3 Sec. Lock/Unlock
Pulse
P6*
Single Unlock Pulse
Double Unlock Pulse
P7*
Normally Closed
Starter Disable
Normally Open (High-
Security Starter
Disable
P8
Not Used
Not Used
P9*
Button 2 = AUX. 1
Button 2 = Remote
Carjack Activation
* This unit must
be powered down
and powered back
up after making
any Jumper Pin
changes from P4
through P9 to
allow the module
to read the new
settings.
Содержание CS-2004 WDC
Страница 17: ......