background image

INSTRUCTIONS Wood's Models

W4950WBP 

W5450WBP 

W6450WBP

W6100WBP

Rev. 0.4 / 01-21 Instruction Sheet 32640AMCRL LVAA 

Glazing, Industrial, Construction

Architectural and Automotive Supplies

Phone Toll Free (800) 421-6144

Fax Toll Free (800) 262-3299

CORPORATE HEADQUARTERS

P.O. BOX 58923, LOS ANGELES, CA 90058-0923

Serving the Industries Worldwide

www.crlaurence.com

SPECIFICATIONS

Product Description

Hand cups use vacuum to lift and carry loads, as follows: A manual pump 

removes air from between the rubber pad and the contact surface; an audio 

alarm and a red line on the pump's plunger serve as low vacuum indicators; 

a check valve allows the user to repump the cup without removing it from 

the contact surface; and a release mechanism allows the cup to disengage 

completely.

  Model 

Pad 

Nominal Dia. 

Max. Load Capacity*

W6100WBP

 

LJ6 

6" [15 cm] 

70 lbs [32 kg]

W4950WBP 

VPFS8L 

8" [20 cm] 

125 lbs [57 kg]

W5450WBP 

G0725 

9" [23 cm] 

150 lbs [68 kg]

W6450WBP 

G0750 

10" [25 cm] 

175 lbs [79 kg]

*Maximum Load Capacity includes a 3:1 safety factor and requires the 

following: attachment on clean, smooth, nonporous flat surfaces; a minimum 

vacuum level of 17½" Hg [-59 kPa]; and a friction coefficient of 1. This rating 

is based on tests of new hand cups attached to the upper, horizontal surface 

of static objects in ideal conditions. Many factors can reduce the capacity, 

including: lifting a load when the cup is attached to a vertical or inclined 

surface; or lifting a load that applies leverage to the cup. See 

crlaurence.com

 

for more information.

Low Vacuum Audio Alarm

Volume: 70 dBA at 36" [91 cm]

Power Source: one AAA size, 1.2-1.5-volt alkaline battery; automatic on/off 

function

Load and Environmental Conditions

Use the cup on clean, relatively smooth, nonporous surfaces, at temperatures 

from 10° to 120° F [-12° to 49° C] and elevation up to 5,000' [1,524 m]. Moisture 

or contaminants can reduce the slip resistance of the cup. Excessive exposure to 

moisture can also damage the audio alarm or reduce its life. Contact an authorized 

dealer or visit 

crlaurence.com

 for more information.

OPERATION

To Test Audio Alarm

Prior to using the hand cup, make sure the audio alarm is functioning 

correctly and can be heard clearly over ambient sound in the work 

environment: While leaving the sound emission holes uncovered, 

depress the plunger slightly. The audio alarm should sound; if not, see 

MAINTENANCE: Service.

To Attach Hand Cup

1) Position the cup on the contact surface so the red line will be visible if it  

   should appear while lifting the load. CAUTION: Test the cup for staining  

   or deformation of load surfaces with light colors or soft coatings.

2) Pump the plunger until the cup attaches completely. When the red line  

   is hidden and the audio alarm is silent, vacuum is sufficient for lifting.

3) Check the plunger frequently to make sure the cup remains securely  

   attached. If the red line appears or the audio alarm sounds while lifting,  

   set down the load immediately and pump the plunger until the red line  

   is hidden and the audio alarm is silent again (see WARNINGS).

To Release Hand Cup

1) Set the load on a secure support.

2) Pull one of the release tabs (on 6" [153 mm] cups) or press the valve

   release lever (on other cups) until the cup disengages completely. 

   CAUTION: Remove the cup when not in use.

MAINTENANCE

Service

Since aging and wear reduce the capacity of the rubber pad, it should be 

replaced at least once every 2 years or whenever damage is discovered (see 

Inspection).

If the audio alarm does not function normally (see OPERATION), make 

sure a working battery is installed correctly (see TO REPLACE BATTERY, 

overleaf). If the condition persists, contact an authorized dealer or visit 

crlaurence.com

 for assistance.

If the hand cup does not function normally, the cup face may be dirty or the 

cup may require service. First clean the cup face according to the directions 

to follow. If the condition persists, contact an authorized dealer or visit 

crlaurence.com

 for assistance.

Cleaning

1) Remove the air filter from the cup face.

2) Use a clean sponge or lint-free cloth to apply soapy water or another  

   mild  cleanser to the cup face; see WARNINGS and crlaurence.com for  

   more information. CAUTION: To prevent liquid from contaminating the  

   pump, hold the cup face-down or cover the suction hole in the filter recess.

3) Wipe all residue from the cup face.

4) Allow the cup to dry and reinstall the air filter.

Inspection

Examine and test the cup regularly to make sure it does not exhibit the 

following faults:

•  failure of audio alarm to function correctly (see OPERATION).

•  corrosion or other indications of battery leakage inside battery  

 

   chamber (see TO REPLACE BATTERY, overleaf).

•  cuts or damage to sealing edges of rubber pad.

•  cracks or dents in handle or pump.

•  reappearance of red line soon after attaching cup.

•  sluggishness or dramatic changes in pump action.

•  excessive glaze or stiffness of rubber pad.

•  air filter missing from cup face.

Correct any faults before using the cup (see Service).

Storage

Store the cup in clean, dry condition within its protective carrying case. If 

the cup is used once a month or less often, remove the battery (see TO 

REPLACE BATTERY, overleaf) and store it separately, to prevent corrosion.

WARNINGS

Failure to observe WARNINGS could damage the hand cup or the load, or 

cause injury to the user.

•  Do not use the cup to lift loads that exceed the Maximum Load Capacity  

   or the effective capacity (see SPECIFICATIONS).

•  Do not use the cup to support a person.

•  Do not place the cup face against surfaces which could damage the  

   sealing  edges.

•  Avoid conditions that could cause the cup to slip or to disengage    

   prematurely, such as: contaminants, cuts or scratches in the cup face or

   contact surface; applying the cup to porous materials; or applying 

   pressure against the cup edge.

•  Do not use the cup to lift when the red line is visible or the audio    

   alarm is sounding. If the red line reappears or the audio alarm 

   sounds frequently, discontinue use and see MAINTENANCE: Service.

•  Do not allow anything to interfere with free movement of the plunger while  

   the cup is attached.

•  Do not touch the release tabs (on 6" [153 mm] cups) or the valve release  

   lever (on other cups) while lifting.

•  Do not attach 10" [254 mm] diameter cups to thin, fragile materials.

•  Do not use harsh chemicals (such as solvents or gasoline) or unauthorized  

   rubber cleaners and conditioners to clean the cup.

•  Avoid contact with battery leaks because they contain chemicals that could  

   damage eyes, skin, clothing or the plunger assembly.

•  Do not expose a battery to excessive heat (see SPECIFICATIONS:

   Environmental Conditions), because this could cause the battery to   

   explode.

Содержание CRL W4950WBP

Страница 1: ...engages completely CAUTION Remove the cup when not in use MAINTENANCE Service Since aging and wear reduce the capacity of the rubber pad it should be replaced at least once every 2 years or whenever damage is discovered see Inspection If the audio alarm does not function normally see OPERATION make sure a working battery is installed correctly see TO REPLACE BATTERY overleaf If the condition persi...

Страница 2: ...ine does appear discontinue use until the problem is corrected See MAINTENANCE Service overleaf for more instructions TO REPLACE BATTERY Test the audio alarm regularly see OPERATION To Test Audio Alarm overleaf and replace the battery as necessary CAUTION Follow the battery manufacturer s instructions for correct handling storage and disposal of batteries 1 Hold the plunger and turn the plunger ca...

Страница 3: ...tosas hasta que la ventosa se desprende por completo PRECAUCIÓN Quite la ventosa cuando no está en uso MANTENIMIENTO Servicio Ya que el envejecimiento y el desgaste reducen la capacidad del disco de goma se debe reemplazarlo al menos una vez cada dos años o siempre que se descubran los daños véase Inspección Si la alarma audible no funciona de manera normal véase FUNCIONAMIENTO asegúrese de que un...

Страница 4: ...deje de usar la ventosa hasta que el problema sea corregido Véase MANTENIMIENTO Servicio al dorso para obtener más instrucciones REEMPLACER LA BATERÍA Prueba la alarma audible con regularidad véase FUNCIONAMIENTO Probar la alarma audible al dorso y reemplace la batería según lo necesario PRECAUCIÓN Cumpla con las instrucciones del fabricante para manejar almacenar y desechar las baterías 1 Agarre ...

Страница 5: ...haltung Da die Tragfähigkeit des Gummisaugertellers durch Alterung und Abnutzung beeinträchtigt wird ersetzen Sie ihn mindestens zweijährlich oder immer wenn eine Beschädigung gefunden wird siehe Kontrolle Falls die akustische Alarmanlage nicht ordnungsgemäß arbeitet siehe BEDIENUNG vergewissern Sie sich dass eine aufgeladene Batterie korrekt eingesetzt ist siehe EINSETZEN DER BATTERIE umseitig We...

Страница 6: ...önt oder der rote Warnring sichtbar wird unterbrechen Sie den Gebrauch bis das Problem behoben ist Für zusätzliche Anweisungen konsultieren Sie WARTUNG Instandhaltung umseitig ERSETZEN DER BATTERIE Prüfen Sie die akustische Alarmanlage regelmäßig siehe BEDIENUNG Prüfen der akustischen Alarmanlage umseitig und ersetzen Sie die Batterie bei Bedarf VORSICHT Befolgen Sie die Anleitungen des Batterie H...

Страница 7: ...Révision Puisque le vieillissement et l usure réduisent la capacité du disque en caoutchouc on doit le remplacer au moins tous les 2 ans ou à n importe quel moment qu on trouve des dommages voir Inspection Si l alarme audio ne fonctionne pas normalement voir MODE D EMPLOI assurez vous qu une batterie en état de marche soit installée correctement voir REMPLACER LA BATTERIE au verso Si la ventouse à...

Страница 8: ... ventouse jusqu à ce que le problème soit rectifié Voyez ENTRETIEN Révision au verso pour trouver des instructions supplémentaires REMPLACER LA BATTERIE Testez l alarme audio régulièrement voir MODE D EMPLOI Tester l alarme audio au verso et remplacez la batterie au besoin ATTENTION suivez les instructions du fabricant de la batterie pour manier emmagasiner et éliminer des batteries correctement 1...

Отзывы: