Servicing Manual: Crewsaver Voyager 275 Lifejacket
Project No: 00154
Date: November 2016
Issue No: 2
Page
of 36
31
Fig 8.1
Hammar Operating Head
Fig. 8.1.1
Check that the indicator is green.
Insert new inflator body with gas
cylinder pointing upward inside the
lifejacket (PFD). Let the sealing ring
rest on the inflator body around the
four lugs.
Fig. 8.1.2
Now check the new manual/
automatic cap as follows:
1. Single point indicator showing
green?
2. Expiry date OK?
If YES is the answer to both
these questions, then proceed
as follows.
If NO get a new cap.
Fig. 8.1.3
Hold the gas cylinder through the
fabric of the lifejacket.
Fig. 8.1.4
Position the replacement cap with
the water inlet valve pointing to the
right and press it FIRMLY onto
the inflator body and sealing ring.
Fig. 8.1.5
While pressing FIRMLY onto the
inflator body turn the BLACK locking
ring clockwise into the locked
position. Pull on the cap to make
sure it has locked onto the inflator
body.
Black locking ring
Single
point
indicator
Green Indicator
Water
inlet
valve
Caution:
Do Not turn
center shaft
8
Section
Please Note: The operating head may not match the images above, but the processes are always as above.