DI20/32-M-A/E-S
Created 11/17/2016 2:29 PM
9
BEGINNING SERIAL NUMBE 07093822
3.
CHECKING TEMPERATURE CONTROL
There are two ways of checking that the temperature control is set correctly.
a.
Place a pyrometer over the thermocouple position and turn the kettle heat on. Watch to
see that the kettle heat shuts off at the correct temperature. Make adjustments as
needed.
b.
The temperature control may be adjusted by observing the operation of the indicator
light as described in the “Temperature Control Operation” section. Adjust the
temperature control so that the kettle heat shuts off 10 to 20 seconds before the corn
finishes popping and the kettle is dumped.
Do not adjust the temperature so high that the pan smokes at the end of the popping
cycle. If set too high (over 500°F or 260oC), the kettle can become a serious fire
hazard.
c.
Observe two or three cycles of correct operation to be certain everything is working
correctly. Your final setting should allow the indicator light to cycle off 10 to 20 seconds
prior to dumping the kettle.
4.
SALT TIMER ADJUSTMENT
For the Salt/Sugar machine, the salt timer is located on the top of all Diplomats under the
top cover marked “Salt Timer.” If the machine pops sugar corn fine but there is a problem
with salted corn, see below.
a.
If the indicator light turns off 30 seconds or more before the corn finishes popping, the
timer is set too low and is in need of adjustment.
b.
There are two adjustments on the timer. The small adjustment knob sets the maximum
time the timer can run. Cretors will normally set this adjustment for 1m.
10s
= 0-10 seconds
1m
= 0-1 minute
10m =
Caution: Never set the timer to 10m
c.
The larger adjustment knob sets the actual run time (percentage of time allowed by the
small adjustment knob). Example: If the maximum setting is set for 1m and the large
knob is set at .5, the timer will run for 30 seconds. In this case, the heat will stay on 30
seconds after the thermostat opens.
5.
SALT/SUGAR WITH ONE POP ADJUSTMENT
a.
If the Salt/Sugar switch is in the sugar position, use the “Digital Temperature Control
Adjustment” section.
b.
If the Salt/Sugar switch is in the salt position, the temperature is adjusted on the One
Pop Timer/Relay.
Содержание DIPLOMAT 20
Страница 22: ...DI20 32 M A E S Created 11 17 2016 2 29 PM 4 BEGINNING SERIAL NUMBE 07093822 ...
Страница 54: ......
Страница 55: ......
Страница 56: ......