Crestron Isys
®
TPS-12L/15L/17L
Wall Mount Touchpanels
Interface Menu
The touchpanel communicates with a control system to activate commands or to
display feedback from components within the system. The communication interface
must be correctly specified or communication will not occur. To set communication
parameters select the
Interface
button located on the SETUP MENU and display the
INTERFACE MENU, shown below.
The Cresnet network identity number (CRESNET ID also known as the Net ID) is
displayed on the INTERFACE MENU. Net ID is the two-digit hexadecimal number.
The hexadecimal number can range from 03 to FE and must correspond to the Net
ID set in the SIMPL Windows program of the Cresnet system. Matching IDs
between touchpanel and SIMPL Windows program is required if data is to be
successfully transferred. Net ID for the TPS-12L/15L/17L is factory set to 03. No
two devices in the same system can have the same Net ID.
INTERFACE MENU
Two buttons adjacent to the hexadecimal display,
UP
and
DOWN
, increase and
decrease the Net ID by one, respectively.
The three buttons on the right define how the RS-232 port can be used; as a console
port (i.e., loading touchpanel projects and firmware), a touch output port
(communication of touch coordinates to an external device), and as a mouse input
port (allows a mouse to control the touchpanel).
The touchpanel usually communicates with a Cresnet system. Occasionally the
touchpanel can be used in a demo mode where it merely displays various menus, but
does not communicate with a Cresnet system. In demo mode, the directory buttons
change pages, but buttons requiring feedback do not work. Two side-by-side buttons,
Enable CRESNET II
and
Disable CRESNET II
, determine communication mode.
Select
Enable CRESNET II
for normal Cresnet communication mode and
Disable
CRESNET II
to set the touchpanel into demo mode. Communication mode is
factory set to
Enable CRESNET II
.
There may be Ethernet devices (i.e., a control system) on the network that
communicates with the touchpanel via CIP (Cresnet Internet Protocol). Two buttons
located on the INTERFACE MENU determine if the touchpanel is capable of this
type of communication. Select
Enable CIP
to permit this protocol recognition and
Operations Guide – DOC. 6355