Страница 1: ... voltage electronic ballast and tungsten halogen transformer loads as well as 1 2 HP motors The device offers the following load ratings l Input Rating 120 VAC Requires Neutral Wire Connection l Output Rating 10 A Max No Minimum Load In the Box 1 HZ SWEX Horizon In Wall Switch with infiNET EX Wireless Communication 120 VAC Additional Items 2 Screw 6 32 x 1 in Truss Head Combo 2054883 1 Spacer Mult...

Страница 2: ...ectrician l Wiring Use copper wire only For supply connections use wires rated for at least 75 C 167 F l Lamp Type For control of permanently installed incandescent magnetic low voltage tungsten halogen electronic ballasts or 1 2 HP motors l Temperature For use where temperatures are between 32 to 86 F 0 to 30 C l Electrical Boxes Devices mount in standard electrical boxes For easy installation us...

Страница 3: ...nd facing up CAUTION Do not overtighten the screws when attaching the keypad to the electrical box Damage to the unit and undesired functionality may occur 5 Place the metal mounting bracket not supplied over the back of the HZ SWEX The two parts of the metal mounting bracket clip together which allows the wiring to remain in place NOTE When installing the HZ FP G faceplate over an old work electr...

Страница 4: ...HZ SWEX Single Gang Installation HZ SWEX Multigang Installation 4 HZ SWEX Quick Start Horizon In Wall Switch with infiNET EX Wireless Communication 120 VAC ...

Страница 5: ...ng There is only one local button available per device Button behavior can be altered by the control system program If the local button is disabled in the control system program and communication to the control system is lost the device will default to the shown behavior When enabled the local button can still act as a remote trigger However LED feedback for the local button will be dictated only ...

Страница 6: ... this can take up to 10 seconds if the device has been previously acquired to a gateway NOTE If a side to side rocker is in the top position either side of the rocker can be pressed and held b Release the button to start the acquire process The top button s LED flashes red slowly to show that the device is actively scanning the infiNET EX network l The top button s LED lights red for 5 seconds to ...

Страница 7: ... Flashes once The device is not joined to the network Ambient Light Sensor Calibration An LED backlight behind each button illuminates engravings The ambient light sensor adjusts the backlight brightness according to the light level in the room The ambient light sensor can be affected by room conditions and should be calibrated manually locally or through programming or the appropriate setting can...

Страница 8: ...ctions Error Code Fault Name Fault Description 2 3 Over Temperature The dimmer has overheated and shut down due to an excessive load Verify that the total load matches the proper ganged rating The dimmer resumes normal operation after cooling 3 3 Device Error The device is experiencing a hardware issue Please contact Crestron Technical Support For general troubleshooting please refer to the follow...

Страница 9: ...nt The product warranty can be found at www crestron com warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source software For specific information visit www crestron com opensource Crestron the Crestron logo Crestron Home Crestron Toolbox Horizon and infiNET EX are either trademarks or registered trademar...