Important Notes
WARNINGS:
l
To avoid fire, shock, or death, turn off power at circuit breaker or
fuse and test that power is off before wiring!
l
New installations should be checked for short circuits prior to
installing an HZ-SWEX switch. With power off, close the circuit and
restore power. If the lights do not work or a breaker trips, check
and correct the wiring or fixture (if necessary). Install the dimmer
only when the short is no longer present. The warranty is void if the
dimmer is installed and operated with a shorted load.
CAUTION:
TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE
DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A
RECEPTACLE, A MOTOR-OPERATED APPLIANCE, A FLUORESCENT
LIGHTING FIXTURE, OR A TRANSFORMER-SUPPLIED APPLIANCE.
ATTENTION:
GRADATEURS COMMANDANT UN BALLAST-AFIN DE
RÉDUIRE LE RISQUE DE SURCHAUFFE ET LA POSSIBILITÉ
D’ENDOMMAGEMENT À D’AUTRES MATÉRIELS, NE PAS INSTALLER
POUR COMMANDER UNE PRISE, UN APPAREIL D’ÉCLAIRAGE
FLUORESCENT, UN APPAREIL OPÉRÉ DE MOTEUR OU UN
APPAREIL ALIMENTÉ PAR UN TRANSFORMATEUR.
NOTES:
Observe the following points.
l
Neutral: The HZ-SWEX requires a neutral connection to operate.
l
Codes: This product should be installed and used in accordance with
appropriate electrical codes and regulations.
l
Installation: This product should be installed by a qualified
electrician.
l
Wiring: Use copper wire only. For supply connections, use wires
rated for at least 75° C (167° F).
l
Lamp Type: For control of permanently installed incandescent,
magnetic low voltage, tungsten-halogen, electronic ballasts, or 1/2
HP motors.
l
Temperature: For use where temperatures are between 32° to 86° F
(0° to 30° C).
l
Electrical Boxes: Devices mount in standard electrical boxes. For
easy installation, use 3-1/2 in. (89 mm) deep electrical boxes. Several
devices can be installed in one electrical box (multigang). For a
smooth appearance, one-piece multigang faceplates (not supplied)
must be installed. When installing into a multigang box, do not fully
tighten the devices to the box until the faceplate has been aligned.
l
Switches: Mechanical 3- or 4-way switches do not work with
HZ-SWEX series switches.
l
Spacing: If mounting one device above another, leave at least 4-1/2
in. (115 mm) vertical space between them.
l
Low Voltage Applications: Operation of a low voltage circuit with all
lamps inoperative or removed may result in current flow in excess
of normal levels. To avoid transformer overheating and premature
transformer failure, Crestron recommends the following:
o
Do not operate low voltage circuits without operative lamps
in place.
o
Replace burned-out lamps as quickly as possible.
o
Use transformers that incorporate thermal protection or
fuse transformer primary windings to prevent transformer
failure due to overcurrent.
2
HZ-SWEX
Quick Start
Horizon™ In-Wall Switch with infiNET EX® Wireless Communication, 120 VAC