Crestron FTI-PWR-D Скачать руководство пользователя страница 19

Crestron 

FTI-PWR-D 

 

FlipTop Power Center - International Version

 

Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange or service without prior authorization 

from CRESTRON. To obtain warranty service for CRESTRON products, contact an 
authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory 
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying 
the nature of the problem, name and phone number of contact person, RMA number and 
return address. 

2.  Products may be returned for credit, exchange or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped freight 
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with 
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect 
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its 
sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any 
products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by CRESTRON, 

shipping by standard ground carrier. In the event repairs are found to be non-warranty, return 
freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials 
and workmanship under normal use for a period of three (3) years from the date of purchase from 
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical 
parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and 
overlay components are covered for 90 days; batteries and incandescent lamps are not covered.  
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON 
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if 
any. 
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended or if it has been subjected to misuse, accidental 
damage, modification or improper installation procedures. Furthermore, this warranty does not cover any 
product that has had the serial number altered, defaced or removed. 
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall 
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages 
inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a 
third party or made by the purchaser for a third party. 
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or 
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the 
unexpired portion of the warranty. 
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or 
implied, nor authorizes any other party to offer any warranty, including any implied warranties of 
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are 
limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. 

Trademark Information

 

All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of 
Microsoft Corporation. Windows 95/98/Me/XP/Vista/7 and Windows NT/2000 are trademarks of Microsoft Corporation. 

 

Operations & Installation Guide – DOC. 6797B 

FlipTop Power Center – International Version: FTI-PWR-D  

  15 

Содержание FTI-PWR-D

Страница 1: ...Crestron FTI PWR D FlipTop Power Center International Version Operations Installation Guide ...

Страница 2: ...o provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does caus...

Страница 3: ...ations 2 Specifications 2 Physical Description 3 Setup 6 Installation 6 Hardware Hookup 11 Operation 12 Problem Solving 13 Troubleshooting 13 Further Inquiries 13 Future Updates 13 Appendix International Power Receptacles 14 Return and Warranty Policies 15 Merchandise Returns Repair Service 15 CRESTRON Limited Warranty 15 Operations Installation Guide DOC 6797B Contents i ...

Страница 4: ......

Страница 5: ...ushed aluminum the FTI PWR D mounts flush in any tabletop surface for a clean discreet appearance Cable Storage Compartment The FTI PWR D provides for extensive connectivity through an easy pull out cable storage mechanism to support a wide range of applications and signal types Eight grommeted holes are provided in the bottom plate allowing for smooth pass through of virtually any type of AV comm...

Страница 6: ...ble FTI PWR D Specifications SPECIFICATION DETAILS Environmental Temperature 5º to 40º C 41º to 104º F Humidity 10 to 90 RH non condensing Enclosure Black metal with black anodized or brushed aluminum cover flush tabletop mountable Dimensions Height Width Depth 142 mm 5 58 in with lid closed 216 mm 8 50 in 170 mm 6 67 in without mounting brackets Weight 2 5 kg 5 5 lbs 2 FlipTop Power Center Intern...

Страница 7: ...n provides information on the connections controls and indicators available on your FTI PWR D FTI PWR D Physical View FTI PWR D Overall Dimensions Top View 216 mm 8 50 in 173 mm 6 83 in 169 mm 6 67 in Operations Installation Guide DOC 6797B FlipTop Power Center International Version FTI PWR D 3 ...

Страница 8: ...ront View FTI PWR D Bottom View 176 mm 6 91 in 203 mm 8 00 in FTI PWR D Overall Dimensions Rear View FTI PWR D Overall Dimensions Side View 76 mm 2 98 in 116 mm 4 57 in 142 mm 5 58 in 205 mm 8 09 in 4 FlipTop Power Center International Version FTI PWR D Operations Installation Guide DOC 6797B ...

Страница 9: ...0V 50 60Hz 10A 2 Grounded AC sockets AC power pass through outlets Specify Socket Type PWR AU B Australia China PWR EU B Europe Schuko PWR FR B France PWR IT B Italy PWR UK B UK Maximum Load 10 Amps 250 Volts AC 50 60 Hz 2 MAX 250V 50 60Hz 10A 1 IEC socket Passes through to front panel AC power outlet Operations Installation Guide DOC 6797B FlipTop Power Center International Version FTI PWR D 5 ...

Страница 10: ...BER QUANTITY Cable Support Plate 2023519 1 Bushings 14 mm 0 55 in ID 20 mm 0 80 in OD 2010496 2 Bushings 10 mm 0 39 in ID 17 mm 0 64 in OD 2011070 2 Bushings 8 mm 0 31 in ID 13 mm 0 50 in OD 2009522 4 Screws 04 40 x 1 4 7 mm 2007158 4 The cable support plate should be installed before mounting the FTI PWR D to a surface The cables are threaded through the cable support plate 1 Place bushings on th...

Страница 11: ...iameter are important considerations If the connector is too long it can interfere with cover operation If the width of the cable strain relief is too similar to the bushing inside diameter the bushing can trap the cable NOTE Do not use the cable support plate without the bushings Example Cable End Operations Installation Guide DOC 6797B FlipTop Power Center International Version FTI PWR D 7 ...

Страница 12: ... to mount in a horizontal surface such as a desk top lectern or podium The following diagram illustrates the required opening size to accommodate the FTI PWR D Use the template supplied with the FTI PWR D 4508463 to make the cutout Cutout Dimensions for the FTI PWR D Not Actual Cutout Template NOTE Be sure to feed the attached power cord and all required cables through the mounting hole before ins...

Страница 13: ... Do not fully tighten the screws These will be used to secure the front and back mounting brackets Refer to the illustration below 2 Position the FTI PWR D in the mounting hole Mounting Bracket Screw Locations 3 Thread a small portion of the 10 32 x 2 51 mm screws 2007293 into the mounting brackets two screws per bracket Refer to the illustration on the following page 4 Slide the mounting brackets...

Страница 14: ... until they contact the underside of the mounting surface enough to secure the unit DO NOT OVER TIGHTEN CAUTION Do not over tighten the 10 32 screws as this may damage the surface and or the unit FTI PWR D Mounting Brackets Installed 10 FlipTop Power Center International Version FTI PWR D Operations Installation Guide DOC 6797B ...

Страница 15: ...er after all connections have been made NOTE For a list of international power receptacles refer to Appendix International Power Receptacles on page 14 NOTE The maximum continuous current from equipment under any external load conditions shall not exceed a current limit that is suitable for the minimum wire gauge used in interconnecting cables The ratings on the connecting unit s supply input shou...

Страница 16: ...d opens 135 degrees allowing full access to cables and power inside Beneath the lid a recessed compartment with eight grommeted holes through the bottom plate allows any type of AV communication data or control cables to be instantly available for connection to your devices The recessed compartment also contains two grounded AC sockets 12 FlipTop Power Center International Version FTI PWR D Operat...

Страница 17: ... advantage of Crestron s award winning customer service team by calling Crestron at 1 888 CRESTRON 1 888 273 7876 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions a...

Страница 18: ...egal Serbia and Montenegro Slovenia Spain Suriname Sweden Syria Tunisia Turkey Ukraine Vietnam 6500643 PWR IT B POWER RECEPTACLE ITALY 250V 16A BLK Chile Ethiopia Italy Libya 6501273 PWR UK POWER RECEPTACLE UK 250V 13A BLK Anguilla Bahrain Botswana Burma Myanmar Cyprus Dominica Falkland Islands Malvinas Gambia Ghana Gibraltar Hong Kong Iraq Ireland Kenya Kuwait Liberia Malawi Malaysia Malta Maurit...

Страница 19: ...s batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was...

Страница 20: ...ron Electronics Inc Operations Installation Guide DOC 6797B 15 Volvo Drive Rockleigh NJ 07647 2023946 Tel 888 CRESTRON 06 10 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Отзывы: