background image

Operate the FlipTop Assembly

To operate the FT2-1200-ELEC-PTL:

1. Open the lid by sliding the lid retraction button away from the FT2

assembly. The lid retracts into the assembly.

2. Access the modules in the FT2 assembly.

3. Close the lid by lifting it vertically and returning it over the FT2

assembly.

Visit the Product Page

Scan the QR code to visit the product page.

FT2-1200-ELEC-PTL

www.crestron.com/model/6511654

Additional Information

Original Instructions
The U.S. English version of this document is the original instructions.
All other languages are a translation of the original instructions.

Regulatory Models: FT2-1200-ELEC-AL, FT2-1200-ELEC-B

Crestron product development software is licensed to Crestron dealers and Crestron
Service Providers (CSPs) under a limited nonexclusive, nontransferable Software
Development Tools License Agreement. Crestron product operating system software is
licensed to Crestron dealers, CSPs, and end-users under a separate End-User License
Agreement. Both of these Agreements can be found on the Crestron website at

www.crestron.com/legal/software_license_agreement

.

The product warranty can be found at

www.crestron.com/warranty

.

The specific patents that cover Crestron products are listed at

www.crestron.com/legal/patents

.

Certain Crestron products contain open source software. For specific information, visit

www.crestron.com/opensource

.

Crestron, the Crestron logo, Cresnet, and FlipTop are either trademarks or registered
trademarks of Crestron Electronics, Inc. in the United States and/or other countries.
Other trademarks, registered trademarks, and trade names may be used in this
document to refer to either the entities claiming the marks and names or their products.
Crestron disclaims any proprietary interest in the marks and names of others. Crestron
is not responsible for errors in typography or photography.

©2021 Crestron Electronics, Inc.

Doc. 9079A

11/05/21

9

FT2-1200-ELEC-PTL

Quick Start

FlipTop™ FT2 Series Cable Management System, 1200 Size, Electrical, Pass-Through Lid

Содержание FlipTop FT2 Series

Страница 1: ...cables to be fully extended while the lid is closed For more information about the accessories please visit www crestron com Crestron FlipTops To configure your FlipTop launch the FlipTop Configuration Tool In the Box 1 FT2 1200 ELEC PTL Additional Items 2 Locking Bars with screws and gaskets 4532619 1 Cable DC Power Splitter 2050094 1 Connector Plug 2003575 1 Holder Power Supply 2048887 1 Power C...

Страница 2: ...he installation or functionality of the FT2 assembly retractors and accessories 2 Using the included cutout template trace an outline of the mounting hole onto the table 3 Cut the mounting hole in the table with an appropriate saw Secure the FlipTop Assembly To prepare the FT2 1200 ELEC PTL and secure it to the table surface 1 Gently remove the bezel before securing the FT2 assembly to the table I...

Страница 3: ...om the table ensure that the screwdriver rotation is set correctly before loosening the swiveling dogs Connect the FlipTop Assembly Access the two network connectors and two power bus barrel jacks on the underside of the FT2 assembly Connect the Network Automate the one touch retractors by connecting all retractors in an FT2 assembly to a control system and a switch or to a DMPS via a single Cresn...

Страница 4: ... the power bus l If connecting one power supply connect the power supply s power cord to the single connector end of the DC power splitter cable Refer to step 1 in Secure the FlipTop Assembly l If connecting two power supplies connect each power supply s power cord to a barrel jack in the power bus 2 Use the two included tie wraps to dress the power cord 3 Slide the power supply into the power sup...

Страница 5: ...2A CBLR GR modules only at the ends of a module row l Dress all cables after installing each module Pass Through Cable Module The FT2A PLT PT pass through modules sold separately enable FT2 CBL PT pass through cables sold separately and other types of interface cables to be installed within the FT2 1200 ELEC PTL Each FT2A PLT PT cable module is packaged with a nylon grommet and a cable plate An em...

Страница 6: ...e with cables that are 10 mm or thinner 1 Open the grommet 2 Insert a cable into the grommet with the connector facing up toward the user 3 Press the grommet back together to secure the cable inside 4 Push the grommet and cable through the hole in the cable plate 5 Insert the cable plate into one of the three slots in the pass through module Choose the appropriate slot based on the length of the c...

Страница 7: ...ld separately allow for cables terminated with standard keystone jacks to be installed in the FT2 assembly The blank and keystone modules each require one empty module slot for installation To install a blank or keystone plate module into the FT2 1200 ELEC PTL l Slide the blank plate module down into the appropriate module slot Use the guide ribs on the front and rear of each module to help positi...

Страница 8: ...se a screwdriver to secure the locking bar screws to the FT2 assembly CAUTION Do not overtighten the locking bar screws Install the Bezel Place the bezel onto the FT2 assembly so that the retractable lid fits inside the bezel opening The bezel is held in place using magnets 8 FT2 1200 ELEC PTL Quick Start FlipTop FT2 Series Cable Management System 1200 Size Electrical Pass Through Lid ...

Страница 9: ...restron dealers CSPs and end users under a separate End User License Agreement Both of these Agreements can be found on the Crestron website at www crestron com legal software_license_agreement The product warranty can be found at www crestron com warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source so...