Crestron
e-control Database Manager SW-DBM
75
••
Appendices
Installation & Reference Guide — DOC. 5823
GoLevel
v
scroller signal
Description
Return to an earlier level of a successive query.
Direction
System to Server
Type
Digital
Value
Pulse
Expected Reply
Scroller blanking
(as per configuration options);
GoLevelEcho
signal pulse;
Scroller refresh with new data;
Done
signal pulse
Comments
The number of
GoLevel
signals,
v
, is the number of successive query levels
defined in the
Configuration Options
window.
The purpose of the
GoLevel
signals is to return to a preceding level. These signals
cannot be used for forward navigation.
Example: From level 2,
GoLevel
1
and
GoLevel
2
are valid but
GoLevel
3
or higher
would be ignored.
See Also
UpLevel, GoLevelEcho, Done
signals