13.
Remove the pre-cut insulation from the grounding wire and
connect it to the electrical box or a ground wire in the electrical
box (the electrical box must be earth grounded).
14.
Attach the unit to the electrical box using the two included
#06-32 x 3/4" oval head slotted screws as shown in the illustration
below.
CAUTION:
Excess wire pinched between the unit and electrical
box could cause a short. Make sure that all excess wire is
completely inside the electrical box and not between the box and
the side of the unit.
15.
Attach an appropriate decorative style faceplate (not supplied).
16.
Remove the backing from the tape on the back of the included
insert. Affix the insert plate into its proper opening in the
faceplate.
DM-RX1-1G in 1-Gang Box (Exploded View)
Mounting Surface
One-Gang Wall Box
(Supplied Seperately)
DM-RX1-1G
(6503434 or 6504685)
Screws (2) #06-32 x 3/4”
(Oval Head (20009684)
Faceplate with Hardware
(Supplied Seperately)
Insert
(4510566 or 4512253)