Operations Guide - DOC. 8162A
Specifications
Detailed specifications for the CNXRMC are listed in the following table.
CNXRMC Specifications
SPECIFICATION DETAILS
Power Requirements
6 Watts (0.25 Amp @ 24 VDC)
Default Net ID
43
Head end video inputs
RJ-45 CAT5 balanced video input (1-4), 100 ohm
impedance, with cable length compensation on three
of the four signals.
All four inputs have video sensor capability (0.25 Vp-p)
Local video outputs
7 RCA connectors labeled A-G, 75 ohm impedance
RS-232 communication
RJ-11 connector
The RS-232 port can be used for the console as well
as RS-232-equipped device communication.
The RS-232 port supports data rates up to 115K baud
and RTS/CTS hardware handshaking.
IR input
1 Mini stereo phone jack–(power, ground, signal)
IR output
4 Mini mono phone jacks–(ground, signal)
Sensor input
Mini Cresnet 2 pin connector accepts power status
feedback from the optional CNXRMCS current sensor
(available separately).
Indicators
PWR (Power), NET and SETUP LEDs
CNXRMC Firmware
CNXRMC.51314t.upz or later
Control System Update Files
1, 2, 3
2-Series Control System
CNMSX-AV/PRO
CNRACKX/-DP
Version 3.015.CUZ or later
Version 5.13.12X.UPZ or later
Version 5.12.63W.UPZ or later
Environmental Temperature
41° to 122°F (5° to 50°C)
Humidity
10% to 90% RH (non-condensing)
Dimensions
Height: 1.94 in (4.93 cm)
Width:
7.48 in (19.00 cm)
Depth: 5.00 in (12.70 cm)
Weight
1.17 lb (0.53 kg)
1.
The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (www.crestron.com). Refer to NOTE below.
2.
Crestron 2-Series control systems include the AV2, CP2, CP2E, MP2, MP2E, PAC2, PRO2, and
RACK2.
3.
CNX update files are required for either CNMSX-AV/PRO or CNXRACKX/-DP. Filenames for
CNX update files have a UPZ extension. To avoid program problems, make certain you are using the
update file with the correct suffix letter (e.g., W or X).
NOTE
: Crestron software and any files on the website are for Authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).
Physical Description
The CNXRMC is housed in a black enclosure with labeling on the front and rear
panels. Controls and LED indicators are located on the front panel; connections are
made to the front and rear panels. (Refer to the illustrations on the next page.) The
unit can be mounted in any convenient orientation. The dimensions are shown in the
physical views illustration on page 4.
Содержание CNXRMC
Страница 1: ...Crestron CNXRMC Room Solution Box Operations Guide ...
Страница 4: ......