background image

Crestron 

CNX-TS

 

Single Gang Temperature Sensor

 

CNX-TS Symbol in Programming Manager 

Programming Manager is where programmers “program” a Creston 
control system by assigning signals to symbols. The following graphic 
shows the CNX-TS symbol in the SIMPL Windows’ Programming 
Manager. 

Detail View of the CNX-TS symbol in SIMPL Windows’ Programming 
Manager 

 

The following two tables list inputs and outputs, respectively, and their 
functional descriptions. 

NOTE

:  All signals listed in the tables are DIGITAL signals unless 

noted. A digital signal can be high (logic level of 1), low (logic level of 
0), and also have rising edge (when it goes from low to high) and falling 
edge (from high to low transitions). 

Operations & Installation Guide - DOC. 8191 

Single Gang Temperature Sensor:  CNX-TS  

  11 

Содержание CNX-TS

Страница 1: ...Crestron CNX TS Single Gang Temperature Sensor Operations Installation Guide ...

Страница 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2002 Crestron Electronics Inc ...

Страница 3: ...p 5 Network Wiring 5 Identity Code 6 Installation 7 Programming 8 Programming with SIMPL Windows 8 Programming with VT Pro e 13 Problem Solving 13 Troubleshooting 13 Further Inquiries 14 Firmware Upgrades 14 Future Updates 14 Software License Agreement 15 Return and Warranty Policies 17 Merchandise Returns Repair Service 17 CRESTRON Limited Warranty 17 Operations Installation Guide DOC 8173 Conten...

Страница 4: ......

Страница 5: ... temperature sensor is a standard Cresnet device and provides temperature sensing when the control system is properly programmed using SIMPL Windows Multiple sensors can be used in a room to give a more accurate temperature reading Functional Summary Multiple temperature sensors for more accurate reading Temperature sensor reports to Cresnet for HVAC monitoring Operations Installation Guide DOC 81...

Страница 6: ...TE after footnote 4 2 Crestron 2 Series control systems include the AV2 PAC2 PRO2 RACK2 CP2 and MP2 3 CNX update files are required for either CNMSX AV Pro or CNRACKX DP Filenames for CNX update files have a UPZ extension and ST CP files are in one EXE or zipped UPZ file To avoid program problems make sure you are using the update file with the correct suffix letter e g S V W X 4 The depth of the ...

Страница 7: ...n 3 556 cm 5 568 cm Approximate measurements with supplied faceplate other faceplates may have different measurements Front View Side Views Sensor Unit 1 788 in 4 158 in 4 542 cm 10 562 cm Speaker Cresnet port TOP NET 24 Y Z G 2 710 in 6 884 cm 1 693 in 4 301 cm Front View Back View Static sensitive device observe electrostatic discharge ESD precautions Operations Installation Guide DOC 8191 Singl...

Страница 8: ...h specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling N11785 NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 4 Single Gang Temperat...

Страница 9: ...rmine the power factor of the entire chain If the unit is a home run from a Crestron system power supply network port the power factor of that unit is the power factor of the entire run The length of the run in feet and the power factor of the run should be used in the following resistance equation to calculate the value on the right side of the equation Resistance Equation R Resistance refer to t...

Страница 10: ...it must match an ID code specified in the SIMPL Windows program The NET ID of the sensor has been factory set to 53 The NET IDs of multiple sensors in the same system must be unique NET IDs are changed from a personal computer PC via the Crestron Viewport Complete the following procedure to change the NET ID NOTE For detailed information on establishing communication between the PC and Control Sys...

Страница 11: ...ch as drafts etc Use type in compliance with local codes After the Cresnet network wiring has been installed and verified use the following procedure to install the sensor refer to illustration on page 4 in a single gang electrical box 1 Turn Cresnet system power OFF 2 Connect the Cresnet cable with supplied mate to the sensor s Cresnet port and the other end to the control system 3 Insert insulat...

Страница 12: ...nd in the CNX TS using VisionTools VT Pro e The following are minimum software version requirements for the PC SIMPL Windows version 2 01 05 or later Requires SIMPL Cross Compiler version 1 1 Library update file 183 or later VT Pro e version 2 4 or later Crestron Database version 15 7 2 or later version 15 8 2 if you use sounds Programming with SIMPL Windows NOTE The following assumes that the rea...

Страница 13: ...iews upper pane PRO2 System View The System Views lower pane displays the PRO2 system tree This tree can be expanded to display and configure the communications ports Expanded PRO2 System Tree C2Net Device Slot in Configuration Manager The C2Net Device Slot can accept a sensor such as the CNX TS Once a sensor is configured in a C2Net Device Slot the slot allows Cresnet communication between the se...

Страница 14: ...X TS device information The NET ID can be changed in this window using the NET ID tab Device Settings Window NOTE SIMPL Windows automatically resets the default NET ID values of a device added to a program if a duplicate device or a device with the same default NET ID already exists in the program Always ensure that the network device NET IDs set via Viewport match the ones in your SIMPL Windows p...

Страница 15: ...ail View of the CNX TS symbol in SIMPL Windows Programming Manager The following two tables list inputs and outputs respectively and their functional descriptions NOTE All signals listed in the tables are DIGITAL signals unless noted A digital signal can be high logic level of 1 low logic level of 0 and also have rising edge when it goes from low to high and falling edge from high to low transitio...

Страница 16: ...d the resulting project loaded Refer to the VT Pro e help file for more information To create additional sound symbols in SIMPL Windows right click on the CNX TS symbol and select Insert Symbol Parameter Field alternatively select Alt CNX TS Symbol Output Signal Descriptions OUTPUT DESCRIPTION PlayingSound Notifies control system that sound file is playing High 1 playing Low 0 not playing Temp x10...

Страница 17: ...e done after an identity code NET ID is assigned to the sensor page 6 or after installation page 7 Problem Solving Troubleshooting The table below provides corrective action for possible trouble situations If further assistance is required please contact a Crestron customer service representative CNX TS Troubleshooting TROUBLE POSSIBLE CAUSE S CORRECTIVE ACTION No temperature indication Wrong NET ...

Страница 18: ...tp www crestron com downloads software_updates asp for the latest version of firmware Not every product has a firmware upgrade but as Crestron improves functions adds new features and extends the capabilities of its products firmware upgrades are posted If you have questions regarding upgrades procedures contact Crestron customer service Future Updates As Crestron improves functions adds new featu...

Страница 19: ...ata or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software is designed as a software development and customization tool As such Crestron cannot and does not guarantee any results of use of the Software or that the Software will operate error free and You ackn...

Страница 20: ...90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its option repair or replace or refund the license fee for any Software found defective by Crestron if notified by you within the warranty period The foregoing remedy shall be your exclusive remedy for any cl...

Страница 21: ...e not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected...

Страница 22: ...Single Gang Temperature Sensor Crestron CNX TS This page intentionally left blank 18 Single Gang Temperature Sensor CNX TS Operations Installation Guide DOC 8191 ...

Страница 23: ...Crestron CNX TS Single Gang Temperature Sensor This page intentionally left blank Operations Installation Guide DOC 8191 Single Gang Temperature Sensor CNX TS 19 ...

Страница 24: ...Crestron Electronics Inc Operations Installation Guide DOC 8191 15 Volvo Drive Rockleigh NJ 07647 08 02 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Отзывы: