Crestron CLW-SLVS1W Скачать руководство пользователя страница 2

CLW-SW1, SWS1, & SLVS1(W/A/B)

 

 

Physical view of CLW-SLVS1 (clockwise from top; Top, Side, 
and Front) 

Physical Description 

The -SW1 and -SWS1 switch contains one large 
pushbutton, a light emitting diode (LED) with software 
adjustable brightness*, and a three-position slider-switch 
as shown after this paragraph. Line voltage connections 
are made at the rear of the switch. Three Class 2 low 
voltage wires, located on the front of the switch, provide a 
Cresnet connection to a control system. The wires can be 
routed to the bottom of the unit for placement outside of 
the wall box. The -SLVS1 is similar to the -SW1 and  
-SWS1 but does not have the slider-switch or the Class 2 
low voltage wires.  

*  LED brightness can only be adjusted through Crestron programming 

software. 

CLW-SW1/SWS1 (L) and CLW-SLVS1 (R) shown in white 

  

 

1.91 in

(4.85 cm)

2.70 in

(6.86 cm)

1.50 in

(3.81 cm)

3.81 in

(9.68 cm)

1.75 in

(4.45 cm)

4.13 in

(10.48 cm)

3.28 in

(8.32 cm)

 

The -SW1, -SWS1, and -SLVS1 mount in a standard 
wallbox and are covered using a decorative faceplate (not 
included). 

Industry Compliance 

Physical view of CLW-SW1/SWS1 (clockwise from top; Top, 
Side, and Front) 

2.38 in

(6.03 cm)

3.28 in

(8.32 cm)

4.13 in

(10.48 cm)

3.81 in

(9.68 cm)

1.50 in

(3.81 cm)

2.70 in

(6.86 cm)

1.91 in

(4.85 cm)

1.75 in

(4.45 cm)

 

This unit has been manufactured to comply with UL’s 
Standards for Safety in Canada and the United States. 
Formal approval is pending. 

Important Notes 

Read before installation. 

• 

Codes: Install in accordance with all local and 
national electrical codes. 
 
Alternate wiring methods may be used for the 
Class 2 wiring connection. The 2002 National 
Electrical Code (Article 725-55) prohibits Class 
2 conductors of the -SW1, -SWS1, and -SLVS1 
to occupy the same outlet box as the power 
conductors. The exception is Part D of Section 
725.55 of the 2002 National Electrical Code, 
which allows a device’s power conductors to be 
installed near (0.25 inch minimum spacing) 
associated Class 2 conductors in the same outlet 
box. Consult the 2002 National Electrical Code 
Handbook and your local electrical inspector 
before proceeding.  
 
Do not use the supplied butt-splice connectors if 
the Class 2 conductors are to be installed in the 
wallbox with the power conductors. Use 

2  

  Stand Alone Wall Box Switch :  CLW-SW1, SWS1, & SLVS1 

Installation Guide – DOC. 6251 

Отзывы: