CLW-SW1, SWS1, & SLVS1(W/A/B)
Physical view of CLW-SLVS1 (clockwise from top; Top, Side,
and Front)
Physical Description
The -SW1 and -SWS1 switch contains one large
pushbutton, a light emitting diode (LED) with software
adjustable brightness*, and a three-position slider-switch
as shown after this paragraph. Line voltage connections
are made at the rear of the switch. Three Class 2 low
voltage wires, located on the front of the switch, provide a
Cresnet connection to a control system. The wires can be
routed to the bottom of the unit for placement outside of
the wall box. The -SLVS1 is similar to the -SW1 and
-SWS1 but does not have the slider-switch or the Class 2
low voltage wires.
* LED brightness can only be adjusted through Crestron programming
software.
CLW-SW1/SWS1 (L) and CLW-SLVS1 (R) shown in white
1.91 in
(4.85 cm)
2.70 in
(6.86 cm)
1.50 in
(3.81 cm)
3.81 in
(9.68 cm)
1.75 in
(4.45 cm)
4.13 in
(10.48 cm)
3.28 in
(8.32 cm)
The -SW1, -SWS1, and -SLVS1 mount in a standard
wallbox and are covered using a decorative faceplate (not
included).
Industry Compliance
Physical view of CLW-SW1/SWS1 (clockwise from top; Top,
Side, and Front)
2.38 in
(6.03 cm)
3.28 in
(8.32 cm)
4.13 in
(10.48 cm)
3.81 in
(9.68 cm)
1.50 in
(3.81 cm)
2.70 in
(6.86 cm)
1.91 in
(4.85 cm)
1.75 in
(4.45 cm)
This unit has been manufactured to comply with UL’s
Standards for Safety in Canada and the United States.
Formal approval is pending.
Important Notes
Read before installation.
•
Codes: Install in accordance with all local and
national electrical codes.
Alternate wiring methods may be used for the
Class 2 wiring connection. The 2002 National
Electrical Code (Article 725-55) prohibits Class
2 conductors of the -SW1, -SWS1, and -SLVS1
to occupy the same outlet box as the power
conductors. The exception is Part D of Section
725.55 of the 2002 National Electrical Code,
which allows a device’s power conductors to be
installed near (0.25 inch minimum spacing)
associated Class 2 conductors in the same outlet
box. Consult the 2002 National Electrical Code
Handbook and your local electrical inspector
before proceeding.
Do not use the supplied butt-splice connectors if
the Class 2 conductors are to be installed in the
wallbox with the power conductors. Use
2
•
Stand Alone Wall Box Switch : CLW-SW1, SWS1, & SLVS1
Installation Guide – DOC. 6251