Crestron CLS-SLVS1 Скачать руководство пользователя страница 6

CLW-SW1, SWS1, & SLVS1(W/A/B)

  

 

Buttons of CLW-SW1, -SWS1, and -SLVS1 

Setup & Programming 

Button

Mode Selection Switch
(-SW1 & -SWS1 Only)

 

Required Software 

Software 

TASK 

REQUIRED SOFTWARE VERSION 

Program control 
system to operate 
CLW-SW1. 

SIMPL™ Windows

®

 version 

2.07.32 or later with SIMPL+ Cross 
Compiler version 1.1 or later and 
Library update 387 or later; Also 
requires Crestron Database 
version 18.1.5 or later. 

Upload program 
and firmware. 

Crestron Toolbox 1.02.29 or later. 

Program with 
simple wizards for 
lighting systems 
using a CLW-SW1 
(optional but 
recommended). 

Crestron D3 Pro™ version 2.1.7 or 
later with D3 Pro Templates 
version 2.0.1 or later. Refer to 
software release notes or Crestron 
website for other required Crestron 
software packages.  

OFF 

When the mode selection switch is in the “OFF” position, 
the pushbutton will not have any function and the load is 
disconnected from the power source. This 

must

 be used 

when changing light bulbs to ensure that the load is fully 
disconnected from power. 

ADJ 

Setup 

When the switch is in the ADJ position, pressing and 
holding the pushbutton will set a delay time for 
deactivating the load when the switch is in the PRE 
position. To set the delay time, press and hold the 
pushbutton for the desired amount of time delay and 
release. When the pushbutton is released, the LED will 
flash three times to confirm the time delay setting. When 
done, return the switch to the PRE position. 

The Net ID of the CLW-SW1 has been factory set to 

82

The Net IDs of multiple CLW-SW1 devices in the same 
system must be unique. Net IDs are changed from a 
personal computer (PC) via the Crestron Toolbox. When 
setting the Net ID, the Net ID of each unit must match an 
ID code specified in the SIMPL Windows program. 

For more details, refer to the Crestron Toolbox help file.  

NOTE:  

If a time delay is not set, the delayed-off feature 

is disabled by default.

 

D3 Pro 

Crestron D3 Pro Software provides all the tools necessary 
to create a complete Crestron Lighting System for 
residential applications. The lighting system includes the 
control system program, touchpanel screens and keypad 
programming, documentation, and real-time lighting 
adjustment capabilities. As with all Crestron software, the 
D3 Pro software provides extensive right-click and drag-
and-drop functionality, in addition to convenient 
keyboard shortcuts for frequently used functions and 
commands. 

PRE 

When the switch is in the PRE position, the load can be 
manually activated and deactivated with the pushbutton. 
Pressing the pushbutton will deactivate the load after a 
delay that was set when the switch was in the ADJ mode. 
During the delay, the LED will flash. Tapping the 
pushbutton during the delay will deactivate the load 
without a delay. 

For additional details, download D3 Pro from the 
Crestron website and examine the extensive help file. 

NOTE:

  The device may be warm to the touch during 

operation. This is normal. 

SIMPL Windows

 

SIMPL Windows is Crestron’s premier software for 
programming Crestron control systems.  

NOTE:  

While SIMPL Windows can be used to program 

the CLW-SW1, it is recommended to use D3 Pro for 
configuring a Crestron lighting system. 

• 

In Configuration Manager, incorporate a CLW-SW1 
into the system by dragging the CLW-SW1 from the 

6  

  Stand Alone Wall Box Switch:  CLW-SW1, SWS1, & SLVS1   

Installation Guide – DOC. 6251A 

Содержание CLS-SLVS1

Страница 1: ...o a Cresnet system and cannot be used without a SWS1 The SLVS1 does not have a mode selection switch and is not programmable It emulates the operation of the SWS1 to which it is connected unless the m...

Страница 2: ...9 68 cm 1 50 in 3 81 cm 2 70 in 6 86 cm 1 91 in 4 85 cm 1 75 in 4 45 cm This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc E239013 This device complie...

Страница 3: ...res rated for at least 75 C Load Type The SW1 SWS1 and SLVS1 are designed for use with permanently installed incandescent fluorescent non dimmable low voltage neon cold cathode HID general purpose fan...

Страница 4: ...om the mounting plate Use a file or sandpaper to remove any excess metal NOTE New installations should be checked for short circuits prior to installing the SW1 SWS1 or SLVS1 With power off close the...

Страница 5: ...w voltage wires connected to the Crestron control system or a Crestron connection block device Push the wires and the splices into a hole in the drywall to provide the necessary separation 5 Push all...

Страница 6: ...re changed from a personal computer PC via the Crestron Toolbox When setting the Net ID the Net ID of each unit must match an ID code specified in the SIMPL Windows program For more details refer to t...

Страница 7: ...hange the Net ID if required The ID code specified in the SIMPL Windows program must match the Net ID of each unit In Programming Manager assign signal names to program the CLW SW1 to operate with the...

Страница 8: ...Wiring a CLW SW S 1 To continue a circuit past a switched light fixture to one or more duplex receptacles connect the switch as shown in the following diagram Figure 2 Adding a Duplex Receptacle Past...

Страница 9: ...teries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the...

Страница 10: ...CLW SW1 SWS1 SLVS1 W A B 10 Stand Alone Wall Box Switch CLW SW1 SWS1 SLVS1 Installation Guide DOC 6251A This page is intentionally left blank...