![Crestron AV2 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/crestron/av2/av2_operation-manual_2683828037.webp)
Crestron
AV2 & PRO2
2-Series Integrated Dual Bus Control System
onto the existing control system in
System Views
, and click
Yes
when prompted to
confirm the replacement.
If the program contains SIMPL+ or User modules, the conversion might generate
error messages. This is because modules and programs often contain symbols with
“ambiguous” signals. For example, the inputs of the Serial to Analog symbol can be
defined as either analog or serial. Although X-Series processors support ambiguous
signals, the 2-Series processor requires all signal types to be strictly defined.
If the program you want to convert contains SIMPL+ or User modules, Crestron
recommends that you first convert each module before converting the larger
program. In this way, the compiler can resolve any ambiguous signals in the modules
and minimize errors when the larger program is converted.
Converting SIMPL+ Modules
1. Open the SIMPL+ module you want to convert.
2. Choose the 2-Series processor as the target by clicking the toolbar
button, as shown in the following illustration.
SIMPL+ Toolbar
NOTE: Y
ou can select both X and 2-Series as the targets, so that the module will work
for both control system types. However, you will be limited to SIMPL+ keywords and
functions that are supported on both systems. If you do not choose a target, then the
module may or may not work, depending on the constructs that are used.
3. Save and compile the module by clicking the
Save and Compile
toolbar button; alternatively, click
Save and Compile
on the
Build
menu (or press
F12
).
Converting User Modules
1. Open the User module you want to convert.
2. Click
Project | Edit Program Header
.
3. Click
2-Series
in the
Target Control System Classes
list box.
You can select other types of control systems as well, but then you will be
limited to symbols that are supported by all of these platforms. The module
may still work on unselected control systems so long as unsupported
symbols are not used. Selecting a control system means that you are
requiring
the module to work there.
Operations Guide - DOC. 5957A
Integrated Dual Bus Control System: AV2 & PRO2
•
33
Содержание AV2
Страница 1: ...Crestron AV2 PRO2 2 SeriesIntegratedDualBusControlSystem Operations Guide ...
Страница 4: ......