-8-
CDVS-5400 SERIES DVR
2.6 Connecting Loopback output (Camera 75 Ohm Terminator)
Each channel’s current input image can directly out to monitor by
‘Ch out’
port. 16 ch outputs are available.
To use this function, connect cable then adjust dip switch.
ON
ON
- ‘On’ : not connected outer monitor.
- ‘Off’ : connected with outer monitor
1 ----------------------------------------------------16
- For a normal image output of each channel, adjust dip switch as
‘On’
status when there are no connection
with monitor.
2.7 Connecting Control Output
Con.
COM
Control Out ( 1 ~ 16)
(+)
External Power Supply ( DC 12V)
Siren, Alarm, Outside Relays
(-)
When a sensor triggered or motion detected, warning or alarm signal is output through the each port of control
out.(need to setup before using. See P35). If devices connected correctly, it works by the output signal from control
out port. (See the picture for connection)
- Use 12V, below 300mA. For controlling lights or other devices, use another external relay.
2.8 Connecting External Sensor
Sen.
COM
Sensor Input ( 1 ~ 16)
16 sensor connections are available. Usually sensor’s one of signal lines connect to com port and connect the
other signal line to a desired sensor input port(1-16).
- Set “NC”, “NO” Type at setup menu.(see p35)
- No power supply from the product. Use individual or provided power for each sensor.