29
When you enter the “XOVER” Sub Menu, you are given three
options for how the band-pass filters can be set. When Set
“BP Filters Independently” is selected, the Channel A and B
high-pass and low-pass filters are individually set.
If you are using the amplifier in a stereo system where both
channels will be set the same, select “Channel B=A” and both
channels will be set at once. Setting the filters for Channel A
also sets Channel B.
If you create a crossover between channels of the amplifier,
select “X-over Freq A Lows B Highs” and crossover frequency
and filter type can be set with one set of controls. Set by
crossover screen, High-pass and Low-pass screens.
Bridge: Input A drives the amplifier in Bridge mode.
Note: Bridge mode is only available on the Pro-LITE
DSP 2.0 and 3.0 amplifiers.
Bridge Mode screen
Save and Apply screen
Set: X-Over Freq A Lows B Highs screen
Set: BP Filters Channel B=A screen
Set: BP Filters Independently screen
Mode continued
Crossover Filters, Band-Pass Filters and Polarity
Unlike the other function Sub Menus, the input mode does
not change until you select “Save and Apply” and return to the
Main Menu.