LM
P
AGE
7
C
ENTURY
S
ERIES
Designed & manufactured in the USA by:
A division of Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
POWER OUT
POWER OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
AVIS : RISQUE DE CHOC ÉLECTRIQUE—NE PAS OUVRIR
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
ATTENTION! POUR ÉVITER LE RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE, NE PLACEZ PAS CET APPAREIL SOUS LA PLUIE OU Á
L'HUMIDITÉ
6
7
2 1
4
5
3
Pin 1 +24V
Pin 2 +20V
Pin 3 Analog
Pin 4 Analog
Pin 5 Digital
Pin 6 +48V
Pin 7 -20V
CONSOLE
G R O U N D
CHASSIS
GROUND
MAXIMUM AC IN:
XCVA04: 415 WATTS
XCVA06: 825 WATTS
+ 48V @ 1
+ 24V @ 6
±
20V @ 6
Model XCVA06
Model XCVA04
±
20V @ 4
+ 24V @ 4
S/N
Designed & manufactured in the USA by:
A division of Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
POWER OUT
POWER OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
AVIS : RISQUE DE CHOC ÉLECTRIQUE—NE PAS OUVRIR
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
ATTENTION! POUR ÉVITER LE RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE, NE PLACEZ PAS CET APPAREIL SOUS LA PLUIE OU Á
L'HUMIDITÉ
6
7
2 1
4
5
3
Pin 1 +24V
Pin 2 +20V
Pin 3 Analog
Pin 4 Analog
Pin 5 Digital
Pin 6 +48V
Pin 7 -20V
CONSOLE
G R O U N D
CHASSIS
GROUND
MAXIMUM AC IN:
XCVA04: 415 WATTS
XCVA06: 825 WATTS
+ 48V @ 1
+ 24V @ 6
±
20V @ 6
Model XCVA06
Model XCVA04
±
20V @ 4
+ 24V @ 4
S/N
To AC Mains
To AC Mains
Interface Cable
To Console
Power Connections
The connections to and from the power supply vary depending on your specific configuration. Multiple power supplies can be
daisy-chained to provide fail-safe protection in the event of a supply failure. When two or more supplies are used, they may be
connected to the same mains voltage since only one of the supplies will actually be feeding the console at any given time.
The connectors on the power supply are “smart” so that either one can be used as the console or interface connection.
Console Cooling
A cooling fan configuration is included in all LM consoles except the LM-12 and the 32-chassis space LM Dual/Stereo models.
Two fans (one at each end of the console) draw air in through the sides of the chassis (under the sidebars). Air is distributed
through the chassis via a “vortex pan”, then proceeds up through the console modules, where the heated air exits the console
chassis.
Once the console is powered up, cooling fans remain on. A rear panel switch permits the fans to be set at low, medium or high
speeds.
There are no filters to change or clean. As with any console, use in dusty/unclean environments should be avoided.
Содержание CENTURY LM
Страница 1: ...CENTURY SERIES OWNER S MANUAL LM...
Страница 20: ...LM PAGE 18 CENTURY SERIES OUTPUT MONITOR A LEFT MONITOR A RIGHT BAL OUT EXT TB IN INSERT RTN INSERT SEND...
Страница 22: ...LM PAGE 20 CENTURY SERIES OUTPUT INSERT RTN MONITOR B LEFT MONITOR B RIGHT BAL OUT OSC IN INSERT SEND...
Страница 24: ......
Страница 25: ...Appendix A Technical Information LM...
Страница 32: ......
Страница 33: ...Appendix B Glossary LM...