Rear Panel
See Appendix E for information specific to model CA18.
10. Output Connectors (Two versions, market dependent)
CA Series amplifiers are supplied with either 5-way Binding Posts or Speakon connectors. Connection to
the binding posts can be made with bare wire, banana plugs, or spade lug terminations. Make connections to
both the Channel A and Channel B terminals for Stereo or Parallel Mode, or a single connection across the
red (“hot”) terminals only of Channels A and B for Bridged Mono Mode. Using Speakon-type speaker
cables, make connections to both the Channel A and Channel B connectors for Stereo or Parallel Mode, or
to the Bridged mode connector for Bridged Mono Mode. See Appendix D and the section on Mode
Selection for more information. NOTE: on the 5-way Output Binding Post version of the CA18, two pairs
of 5-way binding posts are provided for each channel, so that paralleling of speakers is possible.
11. Mode Selection Switch.
This recessed, three-position switch configures the
amplifier for Stereo, Parallel or Bridged Mono Mode operation. Amplifiers are factory-configured for
Stereo Mode. See Appendix D and the section on Mode Selection for more information.
12. Signal Ground Lift Switch.
The recessed signal ground lift switch (factory-set to the ‘ground’ [bottom] position) electrically connects
signal ground to the chassis/AC ground. The top position lifts the amplifier’s signal ground. In a properly
designed system (for safety purposes and to minimize noise), amplifiers should be connected to ground
through the AC line cord. Also, whenever possible, the signal source equipment should share the same AC
ground as the amplifier. In some cases this may not be possible, and a ground loop results. If this happens,
the first step is to move the ground lift switch to the top (‘lift’) position. In this position, the signal ground is
lifted and completely isolated from the chassis/AC ground. Do not change the switch to the ‘lift’ position if
the amplifier and the signal source equipment are on the same AC ground. Should the ground loop problem
persist after the ground lift switch has been set to the ‘lift’ position, then the shield on balanced input lines
should be grounded at one end only (usually the signal source).
Crest Audio CA Series Power Amplifiers
Page 7
Models CA2, CA4, CA6, CA9, CA12, CA18
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS : RISQUE DE CHOC ÉLECTRIQUE—NE PAS OUVRIR
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
ATTENTION! POUR ÉVITER LE RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE, NE PLACEZ PAS CET APPAREIL SOUS LA PLUIE OU Á
L'HUMIDITÉ
CAUTION
A
A B
A B
A
Designed & manufactured in the USA by:
Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
1
3-
2+
+
A
A
B
B
• •
• •
+
+
+
A
B
B
A
A
B
Designed & manufactured in the USA by:
Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
A
A B
A B
A
1
3-
2+
+
• •
• •
B
A
NL4FC
B
A
A
B
643-105
A
A
B
B
10
11
12
13
14
15
Never connect a “hot” (red) output to ground
or to another “hot” (red) output!