MAINTENANCE:

HOW TO CHARGE AND SERVICE THE REFRIGERATION SYSTEM 

Note: The refrigerator is shipped fully charged.

The high-side pressure should be approximately 175 PSI;

low pressure should be approximately 18 PSI at 75° F (24° C) room temperature. 
The charge should be 18 ounces of R134a. 
Service valves are located on the condenser/compressor assembly.

Failure

Probable Cause

1. Power light off

1. Power Cord

2. Compressor off

2. Power supply down

3. Evaporator fan on, Power 

light on and Compressor off

3a. Thermostat defective
3b. Defective start relay (compressor)

4. Compressor on and cabinet 

not cooling

4a. Low charge
4b. Frost build-up on evaporator coil
4c. Evaporator fan defective
4d. Thermostat defective

5. Compressor starts and stops; 

cabinet not cooling

5a. Low Charge
5b. Faulty start capacitor (compressor)
5c. Faulty start relay (compressor)

6. Noisy compressor

6a. Low charge
6b. Defective

TROUBLE-SHOOTING GUIDE

Unit Condition:

Unit is plugged in. Switch is 

ON

.

NOTES: 

1. Thermostat is pre-set at approximately 38°F (3.8°C). Temperature adjustment can only be made by a Service Agency.
2 For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400). 

Содержание R171S1828

Страница 1: ... or ending with S Z and or CAN CONTROL PANEL HOW TO INSTALL THE CABINET Remove all packing material from inside the 1 cabinet INSTALL ALL ANGLES 2 BEFORE UNIT IS TURNED ON Allow enough clearance around cabinet for air 3 flow HOW TO OPERATE Plug cord into proper wall outlet 1 Turn the power switch to ON Light will come 2 on and compressor will start Listen closely for the compressor It will be slig...

Страница 2: ...t Soil Cleaner Method CABINET Inside and Outside Stainless Steel ROUTINE CLEANING Soap Ammonia or mild detergent and water 1 Sponge on with cloth 2 Rinse with water 3 Wipe dry STUBBORN SPOTS AND STAINS Mild abrasive made for stainless steel 1 Apply with damp sponge or cloth 2 Rub lightly GREASE OIL Chemical oven cleaner for stainless steel Follow oven cleaner manufacturer s directions HARD WATER S...

Страница 3: ...ly Failure Probable Cause 1 Power light off 1 Power Cord 2 Compressor off 2 Power supply down 3 Evaporator fan on Power light on and Compressor off 3a Thermostat defective 3b Defective start relay compressor 4 Compressor on and cabinet not cooling 4a Low charge 4b Frost build up on evaporator coil 4c Evaporator fan defective 4d Thermostat defective 5 Compressor starts and stops cabinet not cooling...

Страница 4: ...1221 553 K 1221 553 K Evaporator Assembly for R171SUA10 1828 1416 068 K 1416 070 K Evaporator Assembly for R171SUA20 1856 1416 069 K 1416 071 K Gasket Kit 0861 261 0861 261 Hinge Kit 0519 087 K 0519 087 K Pilot Light Power ON 0766 094 0766 095 Post 0696 237 0696 237 Receptacle 0713 057 0713 058 Switch ON OFF 0808 116 0808 116 Terminal Block 0852 091 0852 091 Thermometer Kit 5238 035 K 5238 035 K T...

Отзывы: