background image

Table 5.3 RX sensitivity 

Parameter 

Min 

Typical 

Max 

Unit 

RX 

sensitivity 

1Mbps 

-94.5 

dBm 

2Mbps 

-91 

Frequency offset error 

1Mbps 

-250 

+300 

KHz 

2Mbps 

-300 

+200 

Co-channel interference 

suppression 

-10 

dB 

 

 

6 Module basic instructions 

  

   KLMKBM-01 module recommends that users can access the network through the 

APP-"zhihui connect" developed by our company configuration. 

Two bulbs are needed for control, and our module needs to be soldered to the 

corresponding lamp board. If the bulb is pre-configured, you need to perform 5 short 

power cycles (on/off every 2 seconds) to reset the bulb. 

 

6.1 Add equipment 

 

 

Click "Add Device" in the upper right corner to select the device you need 

to add or enter the device name directly, such as RGBCW-BLE. 

 

The initial device has entered the distribution network mode as soon as the 

power is turned on, and then the lights start to flash; if it is a secondary 

distribution network, follow the instructions of the distribution network 

diagram, and then click the "start adding device" button. 

 

Search the device, select the corresponding device to ad. 

 

After the connection is complete, click "Finish" --device rename--choose 

a family/room--connection succeeded; 

 

   

 

Содержание KLMKBM-01

Страница 1: ...KLMKBM 01 Bluetooth module instructions Ble mesh ...

Страница 2: ...Version update instructions No Date Content Version 1 2021 05 08 New document V1 0 0 2 3 ...

Страница 3: ...e package 4 3 2 Pin definition 5 4 Electrical parameters 6 4 1 Absolute electrical parameters 6 4 2 Working conditions 6 4 3 Power consumption in working mode 7 5 RF parameters 7 5 1 Basic RF characteristics 7 5 2 RF output power 7 5 3 RF receiving sensitivity 7 6 Module basic instructions 8 Appendix statement 11 ...

Страница 4: ...fault broadcast status It Memorizes networking information and automatically access the network after power on 2 Broadcast cycle adjustable connection interval The key parameters of the module can be configured freely and the efficiency and power consumption can be independently balanced 3 Low power standby Using Bluetooth BLE 5 0 technology 0 1uA in sleep mode 4 RF power consumption TLSR8258 Rx 6...

Страница 5: ...esponding to TL_D7 of IC 4 PA1 I O GPIO port corresponding to TL_A1 of IC 5 B I O GPIO port can be used as LED drive PWM output default corresponding to blue light 6 G I O GPIO port can be used as LED drive PWM output default corresponding to green light 7 WW I O GPIO port can be used as LED driver PWM output default corresponding to warm white light 8 3V3 P Module Power pin 3 3V 9 GND P Ground re...

Страница 6: ...output please contact us 4 Electrical parameters 4 1 Absolute electrical parameters Table 4 1 Absolute parameters Parameter Description Min Max Unit Ts Storage temperature 65 150 VCC Supply voltage 0 3 3 9 V Electrostatic discharge voltage human body model TAMB 25 2 KV Electrostatic discharge voltage machine model TAMB 25 0 5 KV 4 2 Working conditions Table 4 2 Normal working conditions Parameter ...

Страница 7: ...eep sleep mode no RAM reserved 0 4 uA 5 RF parameters 5 1 Basic RF characteristics Table 5 1 Basic RF characteristics Parameter Description Working frequency 2 4GHzISM band Wireless standard BLE 5 0 Data transfer rate 1Mbps 2Mbps Antenna type On board PCB antenna 5 2 RF output power Table 5 2 TX power during continuous transmission Parameter Min Typical Max Unit RF average output power 22 10 10 5 ...

Страница 8: ...nfigured you need to perform 5 short power cycles on off every 2 seconds to reset the bulb 6 1 Add equipment Click Add Device in the upper right corner to select the device you need to add or enter the device name directly such as RGBCW BLE The initial device has entered the distribution network mode as soon as the power is turned on and then the lights start to flash if it is a secondary distribu...

Страница 9: ...roup at the same time 6 3 Single light control After the added device enters the device control page you can perform other operation controls such as switching dimming of a single light 6 4 Other settings Timing countdown can be set device OTA and bulb can be deleted from the network ...

Страница 10: ......

Страница 11: ...d and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by on...

Страница 12: ... changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment IMPORTANT NOTES Co location warning This transmitter must not be co located or operating in conjunction with any other antenna or transmitter OEM integration instructions This device is intended only for OEM integrators under the following conditions Th...

Страница 13: ...as to be aware not to provide information to the end user regarding how to install or remove this RF module in the user s manual of the end product which integrates this module The end user manual shall include all required regulatory information warning as show in this manual ...

Страница 14: ...rations The module must be installed in the host equipment such that at least 20cm is maintained between the antenna and users body and if RF exposure statement or module layout is changed then the host product manufacturer required to take responsibility of the module through a change in FCC ID or new application The FCC ID of the module cannot be used on the final product In these circumstances ...

Страница 15: ...uirements then the end product can be sold legally 2 10 Additional testing Part 15 Subpart B disclaimer The modular transmitter is only FCC authorized for FCC Part 15 Subpart C 15 247 15 207 15 209 and that the host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification If the grantee markets th...

Страница 16: ... if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the in...

Страница 17: ...ided only in a form other than paper such as on a computer disk or over the Internet the information required by this section may be included in the manual in that alternative form provided the user can reasonably be expected to have the capability to access information in that form To ensure compliance with all non transmitter functions the host manufacturer is responsible for ensuring compliance...