ELECTRICAL CONNECTIONS
STEP 1:
Using Listed 90°C minimum rated wire connectors make the following
electrical connections to the lever nuts:
a. For 120/277V connect the black fixture lead to the voltage supply
or Hot 1 (for 208/240/480V wiring).
b. For 120/277V connect the white fixture lead to the neutral supply
or Hot 2 (for 208/240/480V wiring).
c. Connect the green or green/yellow ground lead to ground.
d. If dimming is used; connect the violet dimming positive lead to
the supply dimming positive lead. If dimming is not being used,
ensure to cap off the violet lead
e. If dimming is used; connect the grey dimming
negative lead
to
the supply dimming negative lead. If dimming is not being used,
ensure to cap off the grey lead.
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
DIM (-) GREY
DIM (+) VIOLET
NEUTRAL
OR HOT 2
VIOLET
GREY
SUPPL
Y WIRING
(DIMMING OPTIONAL)
LUMINAIRE