2 of 2
LPN00102X0001A2_A
lighting.cree.com
© 2018 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change.
See http://lighting.cree.com/warranty for warranty and specifications. Cree
®
is a registered trademark, and the Cree logo and
Cree Edge
TM
are trademarks of Cree, Inc.
ELECTRICAL CONNECTIONS
STEP 1:
Make the following Electrical Connections:
a. For 120/277/347V connect the black fixture lead to the
voltage supply position of the terminal block or Hot 1 (for
208/240/480V wiring).
b. For 120/277/347V connect the white fixture lead to the
neutral supply position of the terminal block or Hot 2 (for
208/240/480V wiring).
c. Connect the green or green/yellow ground lead to the
green wire position of the terminal block.
d. If Dimming is an option; connect the violet dimming
positive lead to the supply dimming positive lead.
e. If Dimming is an option; connect the grey dimming
negative lead
to the supply dimming negative lead
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
DIM (-) GREY
DIM (+) VIOLET
NEUTRAL
OR HOT 2
VIOLET
GREY
SUPPL
Y WIRING
(DIMMING OPTIONAL)
LUMINAIRE
STEP 6:
Attach the Mounting Bracket to the customer supplied pendant and pendant
coupling. Secure the pendant fitter to the pendant coupling.
STEP 7:
Install a suitable Listed cord strain relief brushing or bushing in the customer
supplied junction box, and feed the luminaire’s cord through it.
STEP 8:
Connect the cord to the supply wiring per the
Electrical Connections
section.
MOUNTING - HOOK AND CORD MOUNT
STEP 1:
Remove the (4) nuts and washers securing the retained Mounting Bracket
Bolts to the top of the mounting bracket. Remove the top piece of the
mounting bracket assembly from the luminaire. See
Figure 1.
STEP 2:
Install hooks using supplied set screws to the mounting bracket. See
Figure
4.
NOTE:
Do not fully tighten hook set screws until luminaire is balanced. Slid
the hooks until luminaire is properly balanced and tighten set screws when
finished.
STEP 3:
Secure the mounting bracket to the luminaire using the nuts and washers
removed in Step 1 to 180 in/lbs.
STEP 4:
Push down on retainer spring until top of spring is free of luminaire hook.
STEP 5:
Slide hook into securely mounted customer supplied eye hanger and return
retainer spring to original position.
STEP 6:
Install a suitable listed cord strain relief brushing or bushing in the customer
supplied junction box, and feed the luminaire’s cord through it.
STEP 7:
Connect the cord to the supply wiring per the
Electrical Connections
section.
Mount Hook
Power Cord
Hook Set Screw
Retainer Spring
4