OPERATING WARNINGS
IMPORTANT
: Remember to observe all safety warnings and precautions when operating the 

heater on the automatic or timer modes, either attended or unattended since a fire risk exists 

when the heater is accidentally covered or obstructed.
Mains cables are not provided with this heater.
CAUTION: Do not use if either of the heater’s mains power leads become damaged. If the supply 

cord is damaged it must be replaced by the installer or an approved service partner.
Curtains must not come to within 250mm of the top of the heater.
Do not sit or stand on the heater
Do not place objects in contact with the heater.
To maintain stability, it is essential that the heater is placed on a level surface and care should 

be taken to avoid irregular surfaces, such as may result from carpets or tiled surrounds 

partially protruding under the heater.

ELECTRICAL INSTALLATION

The installation of the heater should be carried out by trained personnel.

WARNING - Minimum clearances and IP zone requirements must be adhered to in 

accordance with the current wiring regulations.

WARNING - The electrical installation of this heater must be carried out by a suitably qualified or 

trained electrician, and be in strict accordance with current wiring Regulations. The peak supply 

must be connected via a switched fused spur with a fuse rated suitably for the appliances flex, 

the off-peak supply , via a 20A double pole switch. Failure to follow these instructions will mean 

that the manufacturer’s instructions have not been adhered to. THERE ARE NO EXCEPTIONS.

• This heater must be earthed

• Not suitable for connection via a plug top

• Do not locate the heater immediately above or below a fixed electrical point i.e. socket outlet.

This appliance is intended for installation to a single phase supply only and is not suitable for 

connection to 3 phase supplies.

The heater is not fitted with a mains cable, this should be fitted by the installer. Cable type  

(minimum size) H05VV-F 1.5mm² three core for peak and 2.5mm² three core for off-peak for 

connection to the fixed wiring of the premises through suitable isolation devices positioned 

adjacent to the heater. The supply circuits to the heater must incorporate a double pole isolating 

switch having a contact separation of at least 3mm. 

In installation the supply cord may be cut to the appropriate length for the electrical connection 

point. Excess cable should not be inserted or stored behind the heater.

If, during reassembly of the heater, a part of the thermal insulation shows damage or deterioration, 

it should be replaced by an identical part.

WARNING: All electrical connections to the terminal block must be secure to prevent risk of 

ignition. Tighten to 0.5 Nm.

3

Содержание TSRE050

Страница 1: ...Operating These instructions should be read carefully and retained for future use Note also the information presented on the appliance Creda TSRE Storage Heater Models TSRE050 TSRE070 TSRE100 TSRE125...

Страница 2: ...ater Once the heater has cooled down it will reset automatically it will continue to cycle on and off automatically until the reason for overheating is removed The display screen may flash red to indi...

Страница 3: ...ulations The peak supply must be connected via a switched fused spur with a fuse rated suitably for the appliances flex the off peak supply via a 20A double pole switch Failure to follow these instruc...

Страница 4: ...e if they have been given supervision or instruction concerning use of the appliance Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supe...

Страница 5: ...l RAL7035 anodised Battery Backup 3 3V coin cell battery to backup real time clock Battery life 5 years Supply each 1 N PE 230 240V 50Hz Peak Off Peak Class II IP Rating IPX4 Approvals CE BEAB Warrant...

Страница 6: ...removing the packaging CAUTION SHOULD BE TAKEN NOT TO REST THE HEATER UPON THE ROOM TEMPERATURE SENSOR HOUSING Fig 1b Dispose of packaging in an appropriate way Read these instructions carefully befor...

Страница 7: ...r and 150mm min 75mm either side Ensure the back of the heater is flush against the wall If the skirting board is taller than 120mm and deeper than 15mm it should be cut to accommodate safe installati...

Страница 8: ...rpeted then the carpet should be slit and underlay cut away to allow the feet to rest firmly on the floor Carpet gripper must be locally removed so that the feet may rest in a level position This appl...

Страница 9: ...have been fitted Move the heater away from the wall drill the holes and fit the wall fixings best suited to the application Secure the heater to the wall using correct quantity of screws required per...

Страница 10: ...Not suitable for use on single supply Storage Fan circuit Fan Circuit PEAK L Storage Circuit OFF PEAK L Fan Circuit PEAK N Storage Circuit OFF PEAK N The earth wire should be connected into the earth...

Страница 11: ...for connection Fig 8 IMPORTANT Only heat resistant ordinary polyvinyl chloride sheathed flexible cord should be used the following codes apply IEC 60227 IEC57 or CENELEC H05V2V2 F Maximum Cable Sizes...

Страница 12: ...Fig 9 Fig 10 Fig 11 Fig 12 12...

Страница 13: ...grooves facing upwards and fitting neatly around the element Angle the element upward to fit the energy cell Position the second energy cell in the row against the left hand insulation Place the rema...

Страница 14: ...U Fig 13 Fig 14 Fig 15 Fig 16 14...

Страница 15: ...inner front panel complete with insulation starting at position U and working clockwise Fig 16 Ensure the bottom tabs are located inside the chassis and that the screws are tightly secured down each e...

Страница 16: ...enu Button 3 Back Button 4 Up and Down Arrows 5 Enter Button 6 Advance Button 7 Heating Status NOTE Should the heater fail to operate this may be due to the room temperature being higher than the ther...

Страница 17: ...ges based on the temperature selected showing deep blue through to bright red 5 Enter is used within the menu options to confirm settings On the main screen pressing Enter will display the enabled fea...

Страница 18: ...has a battery backup that will keep the clock running in the event of a mains power outage To adjust the time or date follow the steps below Press the Menu button Select Date Time by pressing the Ente...

Страница 19: ...ble throughout the day and these can be customised for each day of the week Factory default times 06 30 until 09 30 11 00 until 13 00 15 00 until 17 00 18 00 until 22 00 2 Out All Day pre programmed h...

Страница 20: ...t the end of each period select Next to move to the following period When a day is complete select Save to update it Once the first day has been set up it is possible to copy these settings to success...

Страница 21: ...to choose a temperature to be maintained during this period and press the Enter button At the end of the holiday mode the heater will automatically revert back to the previously selected programme Tim...

Страница 22: ...heat is not required press the Advance button and the heater will turn off until the beginning of the next Comfort On period Boost mode provides temporary heating for one two or three hours Auto Boost...

Страница 23: ...le or disable Wireless Connectivity If additional RF Module is connected user will have option to enable or disable RF communications In cases where unauthorised persons may tamper with the control se...

Страница 24: ...able to deliver the required comfort level then it is possible to force the heater to store additional energy In this way more electrical energy is stored during the off peak period and this will inc...

Страница 25: ...Service personnel use only If more than one heater is installed in the same room it is recommended that the smallest capacity heater is set as a Slave Disabled as factory default Rm Temp Offset for S...

Страница 26: ...pacity heater is set as the master and all smaller capacity products are set as slaves Press Menu Back and Enter for 3 seconds to enter the service menu select Slave Mode and press Enter Select Enable...

Страница 27: ...This page is deliberately left blank 27...

Страница 28: ...heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms yo...

Страница 29: ...can sometimes occur immediately above a heater due to the properties of some paints and decorating materials or the presence of environmental impurities in the air such as soot cigarette smoke or ince...

Страница 30: ...e Helpline on 0344 879 35 88 or visit http www credaheating co uk contact and complete the online form For ROI please email serviceireland glendimplex com or call 353 0 1 842 833 We will need details...

Страница 31: ...l receipt as proof of purchase and if required by Creda proof of delivery If you are unable to provide this documentation you will be required to pay for any repair work required Any repair work under...

Страница 32: ...17 Set the cover and the screw safely to one side 2 Slide the catch and pull the module up from the User Interface as shown in Fig 18 3 Move the module clear of the User Interface to access the batter...

Страница 33: ...imer Yes Model Identifier s TSRE050 TSRE070 TSRE100 TSRE125 TSRE150 Unit Heat output Nominal heat output Pnom 0 5 0 75 1 0 1 25 1 5 kW Minimum heat output indicative Pmin 0 0 0 0 0 0 0 0 0 0 kW Maximu...

Страница 34: ...GHT STAT 130 BLUE ROOM THERMISTER FITTED TO MAIN CONTROLLER MODULE BOOST LIMIT STAT 120 GREEN MANUAL CUTOUT 140 USER INTERFACE EARTH EARTH EARTH NEUTRAL PEAK LIVE PEAK LIVE OFF PEAK NEUTRAL OFF PEAK F...

Страница 35: ...35...

Страница 36: ...ntial requirements of EEC Directives 2006 95 EC and 2004 108 EC Customer Helpline 0344 879 35 88 aftersales credaheating co uk www credaheating co uk Glen Dimplex Heating Ventilation Millbrook House G...

Отзывы: