Creda Spa100 Скачать руководство пользователя страница 4

 

7.

 

If you have not yet done so, remove the front cover assembly by undoing the retaining screws at 
the top and bottom of the unit and lifting the cover off.                             

 

Your shower is provided with 2 fixing positions in the backplate (see Diagram 7 on page 9).                                         

The top-fixing hole is a “key-hole” slot (another key-hole is provided for alternate fixing), and 

should be marked and drilled first.  

 

Tighten top screw with head protruding about 10mm from the wall and hook the backplate over 
the screw head. This allows for correct and accurate alignment of your shower before marking 

and fixing the bottom position.  

 

You may not wish to tighten up both screws at this stage as the holes are elongated to allow for 

adjustment after other connections have taken place.  

 

b.

 

PLUMBING 

 

WARNING: ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS 

BELOW BEFORE CONTINUING WITH INSTALLATION. 

 
The heater must be connected to the mains cold water supply. 

This must have a minimum running pressure of 69kPa (0.7 bar, 10 psi) 
and a maximum pressure of 690kPa (7.0 bar, 100 psi). 

 

WARNING: BEFORE CONNECTING THE PIPE WORK TO THE SHOWER,                                     

ENSURE THAT THE PIPE WORK IS FULLY FLUSHED OUT. 

 

1.

 

Unscrew the “Red Cap” from the shower outlet pipe and discard it in a suitable manner.                 

This has been used to seal the shower during transit, and is no longer required. 

 

2.

 

It is recommended that a WRAS (Water Regulations Advisory Scheme) listed isolating valve is 

fitted to the incoming mains cold water before the shower unit.                                            

This will allow the unit to be serviced or exchanged without having to turn off the water at the 
water stop valve. 

 

3.

 

The heater can be fed from a header tank provided this has a minimum head of 7 metres (23ft). 

 

4.

 

Ø15mm copper or stainless steel pipe should be used.                                                                                               
To avoid cross threading, DO NOT REMOVE the nut from the elbow when positioning the pipe.                                                              

If top entry is required, turn the elbow 180° into the required position.                                                                               

If rear entry is required, treat as top entry with an additional “Yorkshire” elbow (soldered type) 

for fitting into the rear channel.                                                                                                                         
In multiple installations, correct pipe work sizes should be calculated to maintain adequate flow 

to each shower. 

 

5.

 

It is permissible to use a WRAS (Water Regulations Advisory Scheme) approved sealant sparingly 

whilst avoiding excess finding its way into the shower operating parts. 

 

6.

 

With isolating valve connected, 

flush the pipe work through to remove any particles etc

before making the final connection to the shower.                                                                                                                                                     
Blockage in the water ways (particularly the handset and solenoid valve) will prevent the heater 

working properly.

 Note: You may be charged for a service call if it is due to incorrect installation.

 

 

7.

 

The shower is designed to have an open outlet and should only be used with “Creda” 

recommended fittings.                                                                                                                         

Do not connect the handset until after the shower front cover and corner section are fitted. 

 

WARNING: DO NOT FIT A TAP ON THE SHOWER OUTLET.  

 

WARNING: TAKE CARE TO AVOID RESTRICTING THE OUTLET OF THE                                   

PRESSURE RELIEF DEVICE 

 

WHAT TO DO IF THINGS GO WRONG (2) 

CREDA AFTER SALES SERVICE 

 

 

PROFESSIONAL SERVICE 

 

If the previous “Self Help” checks fail to restore the performance, you should seek professional help. 

 

The person who installed the shower is probably the best one to investigate and correct it and is 
certainly the person to contact if you have had a problem in the guarantee period. 

 

The following additional checklist is provided for the benefit of the qualified service person. 

 

WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR                                           

BEFORE REMOVING THE COVER TO MAKE CHECKS 

 

Water too HOT 

Water flow restricted by blockage in filter of solenoid valve. 

Switch off water, loosen inlet connection to solenoid, remove filter in solenoid 
with long nosed pliers and flush clean. 

Water too COLD 

Check circuit through thermal cut-out. 

Check circuit through microswitches on the pressure switch. 
Check each element circuit. 

Check tightness of electrical connections. 

No control over  
water flow 

Check Drive Gite is correctly engaged into Control Knob (see Diagram 5) 
Undo headworks of stabiliser valve. 

Check stabiliser is in place and remove any debris in valve. 

Water discharges 

from pressure     
relief valve 

Check for cause of high pressure and remove it. 

Blockage on outlet e.g. blocked shower handset.  
Replace the pressure relief disc (not covered by guarantee). 

Water does not 

flow when outer 

knob “A” is turned 

Check circuit through solenoid coil. If defective then replace. 

Check circuit through microswitches. If defective then replace. 

Power supply not reaching shower. 

 

 

We offer a technical advisory service on the telephone to 

installers and other customers with problems in the field. 

 

RING 0844 372 7766 (UK ONLY) 

RING YOUR LOCAL DEALER (Export Variants) 

 

Some spare parts (see later section) can be supplied 
against Credit or Debit cards. 

 

RING 0844 372 7750 (UK ONLY) 

 

Remember to quote the exact type of shower, as written 

on the front of the shower and on this leaflet.                                                     

The model and serial number are located on the bottom 
face of the shower. 

Make a note of those numbers here, and be sure to quote 
them if you call for advice.  

 

Model Number: 53-67_ _ _ _ _ _ _ _ _ _ _ _ _ _ 

 

Serial Number:  _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _   

 

Note: You may be charged for a service call 

           if you do not have the serial number.

 

Отзывы: