1.

 

Water is heated instantaneously as it flows over the                                                                                
heating elements in the copper cylinder (Diagram 8). 

 

2.

 

The heaters are only switched on when sufficient                                                                                  

water is flowing.                                                                                                                                                           

This is done automatically with a switch which                                                                               

works on water pressure and is indicated by the                                                                                   
neon light illuminating depending on the power                                                                                               

selected by outer knob “A”. 

 

3.

 

The water is turned on and off by the solenoid                                                                              

valve built into the shower.                                                                                                                                   

This is switched on when outer knob “A” is                                                                                            
clicked clockwise. 

 

4.

 

The flow of water is automatically held at the level set                                                                                               

by the user even though the supply pressure may vary                                                                            

(see “Effect of Other Water Devices on Incoming Water Supply”). 

 

5.

 

If the water supply falls below a set limit, the pressure                                                                        

switch will operate and switch off the power to the elements.                                                                

This is indicated by the neon light going out (see “Effect of Other Water Devices on Incoming 
Water Supply”). 

 

6.

 

As a further safeguard

, a thermal cut-out switches the power off if the water temperature 

climbs above the set limit. This cut-out, which gives an audible click, may also operate due to 

residual heat when the shower is switched off.                                                                                                  

It will reset itself if water is run through the shower for 10 to 20 seconds. 

 

7.

 

The pressure relief device is to safeguard against abnormal pressure conditions, and provides a 
level of appliance protection should an excessive build of pressure occur within the shower. 

 

Effect of Seasonal Incoming Water Temperature Changes 

 

The required water temperature is achieved by adjusting the rate of water flow.  

Diagram 9 shows the principle involved in relating temperature rise to flow rate.                                 
The higher the water rate the lower the temperature and vice versa.                                               

The temperature of the water supplied from the mains can vary considerably                                      

throughout the year from 5 to 20°C.                                                                                                                    
This means that in the winter, flow rate will be less than in the summer to                                                            

achieve the same outlet temperature.                                                                                                                                                              
In summer the “  (medium)” power setting may give adequate hot water. 

 

Effect of Other Water Devices on Incoming Water Supply 

 

Your shower is 

designed to stabilise temperature

 changes caused by water pressure 

fluctuations. These can result from toilets being flushed or taps being turned on and off.                                 

When this happens your showering temperature will be held within a controlled band, provided that 
the minimum pressure required by the shower is maintained. 

 

Your shower requires a minimum running pressure of 69kPa (0.7 bar, 10 psi).                                                                                    

At pressures above 69kPa (0.7 bar, 10 psi) it will minimise temperature fluctuations as detailed 

above. If the water pressure falls below 69kPa (0.7 bar, 10 psi) it is likely that the pressure switch 

will turn off the power to the heating elements, resulting in a cold shower.                                                                                               
This will be indicated by the neon light going out. 

 

HOW YOUR 

SPA100 

 SHOWER WORKS 

 

 

 

 
 
 

WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY 

QUALIFIED PERSON. 

 

WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE SUBJECTED TO 

FREEZING CONDITIONS 

 

We recommend that the installation is done in the following sequence. 

 

a. Fixing the shower to the wall    b. Plumbing   c. Electrical connections 

 

a.

 

FIXING THE SHOWER TO THE WALL 

 

1.

 

Position the riser rail at a convenient height for majority of users                                                                       

as detailed in Diagram 1a and mark its position. 

 

2.

 

Position the heater so that the top of the unit is horizontal and level                                                                               

with, 

or a maximum of 0.6 metres (2ft) below the top of the                                                                       

riser rail

. Choose a flat piece of wall to avoid the possibility of                                                           

distorting the backplate thus making the front cover a poor fit. 

 

3.

 

Adjust the position to get the most convenient arrangement taking                                                                                      

the following into account. 

 

The heater must not be mounted in the handset direct spray. 

 

 

The handset must not be able to come into contact with used water                                                                                   

in the cubicle, bath or basin. If it can, even after the hose has been                                                            

retained by the retaining ring (see Diagram 1b), then a vacuum                                                 
breaker must be fitted (available from us). 

 

4.

 

Fix the riser rail with screws provided.                                                                                                                                               
The fixing holes at the base of the brackets will be disclosed by                                                                                            

removing the plastic fronts. Assemble as shown in Diagram 1b.                           

5.

 

Decide the position of the electrical cable into the unit. If top or bottom entry is chosen 
(according to Diagram 7 on page 9), cut away the walls in the backplate as shown in Diagram 2. 

 

6.

 

Decide the position of entry of the cold water pipe into the unit.                                                                   
If top, cut away the backplate. If rear, please read the section on plumbing.                                                                                           

If bottom, remove the front cover (complete with knobs) and cut away the detachable corner 

section as shown.  

HOW TO INSTALL YOUR 

SPA100 

 SHOWER 