background image

Note the way the bricks are positioned in the heater.  Otherwise they 

will not fit.

9

11

Now, place in position the front rank of bricks, again 

pushing them back to make room for the front insulation 

slab which is attached to the front panel. 

Temporarily remove one central element to provide 

access for the rear rank of bricks.

Loosen terminals on one of the elements and remove this to 

allow installation of rear rank of storage bricks.  On heaters 

with 3 or 4 elements remove one of the central ones.

8

10

Put in place the rear rank of bricks, pushing them well back 

against  the  rear  insulation.    Replace  the  element,  making 

sure that the connection is tight.

Содержание Newera TSR12AW

Страница 1: ...ds EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC GDC Grou...

Страница 2: ...avoid overheating do not cover the surfaces of the heater Do not put clothes fabrics or any other materials on the heaters Do not place objects in contact with the heater Do not position the heater w...

Страница 3: ...of cleaning with vacuum cleaners etc underneath the heater Carpet gripper should be removed from behind the heater feet BRICKS The heater casing and the heater storage bricks with which it must be fit...

Страница 4: ...on floor proper lay carpet over foot slitting it as shown it is unnecessary to cut carpet away Stand the heater against the wall in its intended position Mark the position of the two outside corners...

Страница 5: ...ontact with the casing A shelf unit is separately available for fitting above heaters 4 When bracket is securely fixed replace the heater under the bracket angle and align screw holes on heaters ends...

Страница 6: ...WITCHED ON ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM MAINS TERMINALS IMPORTANT for earthing loosen the earth screw sufficiently to wrap the mains earth wire aro...

Страница 7: ...front panel Temporarily remove one central element to provide access for the rear rank of bricks Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage...

Страница 8: ...NS WITH THE FLAT ON THE KNOB BOSS 12 13 SETTING THE CONTROLS The controls are located under the lockable flap at the right hand corner of the top panel To adjust the controls on the heater use a coin...

Отзывы: