Creda Newera TSR12AW Скачать руководство пользователя страница 6

 

 

     

Charge   

Rated

 

 

     Period   

Charge

79341/4/6S         7 hours    

12 kWh

79351/4/6S         7 hours    

18 kWh

79361/4/6S         7 hours    

24 kWh

Some  heater  variants  may  have  other  charge 

periods  or  acceptances.    See  heater  rating 

plate.

Remove  the  inner  front  panel;  this  carries  on  it’s  inner 

face the front insulation slab.  Handle this with care, the 

insulation must not de damaged.  

REMOVE  ALL  THE  PACKING  CARDBOARD  FROM 

INSIDE THE STORAGE BRICK COMPARTMENT, IF LEFT 

INSIDE  IT  WILL  BE  SET  ON  FIRE  WHEN  THE  HEATER 

IS  SWITCHED  ON.    ENSURE  THAT  ALL  PACKAGING 

MATERIAL  IS  REMOVED  FROM  THE  BRICKS  BEFORE 

FITTING THEM.

MAINS TERMINALS

IMPORTANT: for earthing, loosen the earth screw sufficiently 

to wrap the mains’ earth wire around it between flat washer 

and cup washer, and retighten the earthing screw.

WARNING

6

7

CONNECTING THE MAIN’S SUPPLY CABLE

Feed  the  mains  cable  through  the  cable  clamp  and  make 

connections  as  marked  on  the  heater.    Pull  back  any  slack 

through the clamp and tighten clamping screw.   Make sure 

clamp  is  tightening  on  outer  sheath  of  cable  and  not  on 

individual conductors.

79361/4/6S

79351/4/6S

79341/4/6S

ENSURE THAT CABLE CLAMP 
IS SECURELY ATTACHED TO 
THE CHASSIS OF THE HEATER.

Содержание Newera TSR12AW

Страница 1: ...ds EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC GDC Grou...

Страница 2: ...avoid overheating do not cover the surfaces of the heater Do not put clothes fabrics or any other materials on the heaters Do not place objects in contact with the heater Do not position the heater w...

Страница 3: ...of cleaning with vacuum cleaners etc underneath the heater Carpet gripper should be removed from behind the heater feet BRICKS The heater casing and the heater storage bricks with which it must be fit...

Страница 4: ...on floor proper lay carpet over foot slitting it as shown it is unnecessary to cut carpet away Stand the heater against the wall in its intended position Mark the position of the two outside corners...

Страница 5: ...ontact with the casing A shelf unit is separately available for fitting above heaters 4 When bracket is securely fixed replace the heater under the bracket angle and align screw holes on heaters ends...

Страница 6: ...WITCHED ON ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM MAINS TERMINALS IMPORTANT for earthing loosen the earth screw sufficiently to wrap the mains earth wire aro...

Страница 7: ...front panel Temporarily remove one central element to provide access for the rear rank of bricks Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage...

Страница 8: ...NS WITH THE FLAT ON THE KNOB BOSS 12 13 SETTING THE CONTROLS The controls are located under the lockable flap at the right hand corner of the top panel To adjust the controls on the heater use a coin...

Отзывы: