WARNING – THIS APPLIANCE MUST BE EARTHED.
Your appliance should be checked to ensure that the voltage corresponds with your
supply voltage, this is stated on the rating plate, which is situated on the front of the
plinth. The cooker must be connected by a NICEIC registered contractor to a suitable
double-pole control unit, with a minimum rating of 30A and a minimum contact
clearance of 3mm, which should be fitted adjacent to (but not above) the cooker, in
accordance with IEE regulations.
The power supply cable should conform to B.S.6004 with a conductor size of 6mm
2
.
The control unit should be easily accessible in the event of an emergency.
This appliance conforms to EN 55014 regarding suppression of radio and television
interference.
Access to the mains terminals is gained by removing the rear access cover.
The mains cable must pass through the cable clamp adjacent to the terminal block.
Sufficient cable should be used to allow the cooker to be pulled out for servicing.
Ensure that the mains cable is routed away from any brackets affixed to the rear panel
(especially the vent outlet covers) and is not trapped to the rear wall when pushing the
cooker into position between cabinets.
Siting the Cooker
Your cooker is heavy, so it would be advisable for two people to move it. The cooker is
fitted with rear wheels and will slide into position easily. Movement of your cooker is
most easily achieved as follows. Open the Grill/Oven door sufficiently to allow a
comfortable grip on the underside front edge of the oven roof, avoiding any grill
elements or oven interior furniture, and then lift and slide back at the same time.
Your cooker must stand on a flat surface so that the hob is perfectly level, and the
cooker is stable and cannot be rocked, this is easily achieved by adjusting the 3 feet
which are under the front of the cooker, if necessary.
The cooker is designed to fit between kitchen cabinets spaced 1000mm apart. The
space either side need only be
sufficient to allow withdrawal of
the cooker for servicing. It can be
used with cabinets one side or
both. It can also be used
freestanding.
This cooker is a class X appli-
ance, as such adjacent side walls
which project above hob level,
must not be nearer to the cooker
than 65mm and should be
protected by heat resistant mat-
erial. Any overhanging surface or
cookerhood should not be nearer
650mm.
Installation – Electrical
450mm
Min
5