6

Stand the radiator on its feet and against a wall.

Remove the securing screws along the bottom edge

of the front panel.

7

Swing bottom of panel slightly away from the rest of

the radiator (Fig. 7

A

) and lift upwards to unhook the

top edge (Fig. 7

B

).

6

7

A

7

B

5

Stand the radiator on its feet and remove packaging

by sliding over the top of the radiator.  Remove all

additional internal protective packaging.

5

8

Ensure the electronic components are not damaged

when removing the panel.  Carefully place the panel

to one side.  Check that the mains supply cables are not

damaged.

If they are to be replaced only heat resistant cable must be

used (min T85).  Refer to sections 4, 21 and 22 for fitting the

off-peak and radiant element cables.

9

Position radiator against wall in intended final position,

ensuring it is on a firm base and taking note of the

minimum fixing dimensions (see front page).

If the floor is carpeted it is important that the feet are

positioned firmly and securely.  The feet may rest on

top of the carpet, however  carpet gripper should be removed

around the feet so that the radiator rests in a level position.

10

7

D

Carefully disconnect the

radiant element connector

from the front panel (Fig. 7c).

(See label on bottom of heater

and graphic 7

D

 below).

7

C

Содержание Eco-Response ER300

Страница 1: ...eing fixed Some modern internal building materials are very low density block and require specialised fixing devices to provide a safe secure installation WARNING If during any reassembly of the radia...

Страница 2: ...tions for Electrical Equipment The radiator is fitted with two flexible cables for connection to the fixed wiring of the premises through suitable switched connection boxes positioned adjacent to the...

Страница 3: ...3 Circuit Diagram...

Страница 4: ...theundersideoftheradiatorensuringitissecure during transit The off peak mains cable will be secured with cable ties Prior to installing the radiator unclip the direct acting mains cable do not remove...

Страница 5: ...hat the mains supply cables are not damaged If they are to be replaced only heat resistant cable must be used min T85 Refer to sections 4 21 and 22 for fitting the off peak and radiant element cables...

Страница 6: ...panel Fig 11D see Fig 11A for wall spacer bracket orientation 11E F Carefully guide the radiator towards the drilled hole and screw part way to the wall Fig 11E 11F 11D 11E 11F 11G NOTE UNDER NO CIRC...

Страница 7: ...UMSTANCES SHOULD THESESCREWSBEREMOVED WITHOUT FIRST REMOVING ALL ENERGY RETENTION CELLS FROM THE RADIATOR Solid brick High density block walls These must be drilled and plugged with the Rawlplug No 10...

Страница 8: ...l packaging Fig 13C taking care not to damage the insulation attached 13A 14 Lift out the elements from the base insulation and rotate forwards DO NOT DISCONNECT THE TERMINALS 14 13B 13c 15 Carefully...

Страница 9: ...stalled DO NOT attempt to reposition the radiator without first unloading the energy retention cells and obtaining the services of a competent electrician 17 16B 19 In its factory default setting the...

Страница 10: ...ng the cable Cut the mains cables to length Ensuring the electricity supply is disconnected connect the free end of the mains cable to a suitable double pole switch adjacent to the radiator reinstate...

Страница 11: ...PCB Bracket from the bottom of the outer front Remove the wire from the connector block and earth screw Using a pair of pliers remove the cable grip from the bracket The replacement cable will be eith...

Страница 12: ...electrical connections are secure Only then phone the customer help line for assistance Reconnect spur and switch on radiator CHECKPROCEDUREFORINSTALLERSFOLLOWINGINSTALLATION 2 To check the radiant pa...

Отзывы: