background image

 - 1 -

Eco-Response Radiator
Models: ER300, ER400 and ER500

Installation Instructions

86576    Issue 1

Dimensions 

(including clearances diagram)

(millimetres)

Models

Specification

ER300

1.3kW / 0.28kW

ER400

1.95kW / 0.34kW

ER500

2.6kW / 0.39kW

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

NOTE ALSO THE INFORMATION GIVEN ON THE APPLIANCE

These instructions should 

not 

be left with the user, as this would invite the dismantling and servicing by unqualified persons.

There is a separate instruction leaflet which should be left with the user explaining how the radiator should be operated.

IMPORTANT SAFETY ADVICE

WARNING - 

This radiator is VERY HEAVY.  In order to maintain stability and to ensure its future safety in use, it is essential

that the radiator is FIXED SOUNDLY TO A WALL and that the feet are mounted on a FIRM, LEVEL SURFACE.  Care should

be taken to avoid irregular surfaces, such as may result from tiled surrounds partially protruding under the radiator.  It is

important that the following instructions are strictly followed.

WARNING 

– It is important that the fixing device chosen is appropriate to the wall material to which the radiator is being

fixed.  Some modern internal building materials are very low density block and require specialised fixing devices to

provide a safe, secure installation.

WARNING

 – If during any reassembly of the radiator, a part of the thermal insulation shows damage or deterioration which

may impair safety, it should be replaced with an identical part.

WARNING 

– This radiator must not be located below a socket outlet.

Suggested Wall Fittings 

(see page 7 for further information)

Solid brick/block:

  No. 10 Rawlplug fibre inserts (provided).  5.5mm drill bit.  Drill 8mm deeper than rawlplug length.

Plasterboard:

  If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 intersets.

For other wall types seek specialist advice.

DO NOT COVER OR OBSTRUCT

 the surfaces of the appliance.

DO NOT POSITION

 under windows where curtains may contact the radiator (see minimum clearances above).

DO NOT PLACE OBJECTS

 in contact with the radiator.

Wall, Curtains or Furniture

Curtains

Shelf or Overhang

Furniture
or other
obstruction

110mm

150mm
min.

250mm
min.

75mm
min.

75mm
min.

A

B

C

TO ENSURE THIS APPLIANCE IS OPERATING CORRECTLY, IT IS ESSENTIAL TO PERFORM THE CHECK PROCEDURE DETAILED ON

THE BACK PAGE OF THIS INSTRUCTION. THIS MUST BE COMPLETED BEFORE NORMAL OPERATION COMMENCES.

Model

Height A

Width B

Depth C

ER300 712mm

600mm

130mm +10mm

ER400 712mm

830mm

130mm +10mm

ER500 712mm

1050mm

130mm +10mm

Содержание Eco-Response ER300

Страница 1: ...eing fixed Some modern internal building materials are very low density block and require specialised fixing devices to provide a safe secure installation WARNING If during any reassembly of the radia...

Страница 2: ...tions for Electrical Equipment The radiator is fitted with two flexible cables for connection to the fixed wiring of the premises through suitable switched connection boxes positioned adjacent to the...

Страница 3: ...3 Circuit Diagram...

Страница 4: ...theundersideoftheradiatorensuringitissecure during transit The off peak mains cable will be secured with cable ties Prior to installing the radiator unclip the direct acting mains cable do not remove...

Страница 5: ...hat the mains supply cables are not damaged If they are to be replaced only heat resistant cable must be used min T85 Refer to sections 4 21 and 22 for fitting the off peak and radiant element cables...

Страница 6: ...panel Fig 11D see Fig 11A for wall spacer bracket orientation 11E F Carefully guide the radiator towards the drilled hole and screw part way to the wall Fig 11E 11F 11D 11E 11F 11G NOTE UNDER NO CIRC...

Страница 7: ...UMSTANCES SHOULD THESESCREWSBEREMOVED WITHOUT FIRST REMOVING ALL ENERGY RETENTION CELLS FROM THE RADIATOR Solid brick High density block walls These must be drilled and plugged with the Rawlplug No 10...

Страница 8: ...l packaging Fig 13C taking care not to damage the insulation attached 13A 14 Lift out the elements from the base insulation and rotate forwards DO NOT DISCONNECT THE TERMINALS 14 13B 13c 15 Carefully...

Страница 9: ...stalled DO NOT attempt to reposition the radiator without first unloading the energy retention cells and obtaining the services of a competent electrician 17 16B 19 In its factory default setting the...

Страница 10: ...ng the cable Cut the mains cables to length Ensuring the electricity supply is disconnected connect the free end of the mains cable to a suitable double pole switch adjacent to the radiator reinstate...

Страница 11: ...PCB Bracket from the bottom of the outer front Remove the wire from the connector block and earth screw Using a pair of pliers remove the cable grip from the bracket The replacement cable will be eith...

Страница 12: ...electrical connections are secure Only then phone the customer help line for assistance Reconnect spur and switch on radiator CHECKPROCEDUREFORINSTALLERSFOLLOWINGINSTALLATION 2 To check the radiant pa...

Отзывы: