![Creda Aquawave White Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/creda/aquawave-white/aquawave-white_installation-and-user-manual_2682236008.webp)
8
HOW TO MAINTAIN YOUR
AQUAWAVE
SHOWER
ASSEMBLY OF ACCESSORIES
Diagram 5a
Contemporary Colour Model
Fitting Instructions
(Refer to the separate fitting instruction sheet
packed with the accessories for more details)
1. Establish height of riser rail to suit user
requirements.
This should be a maximum of 0.6 metres
(2ft) above the level of the heater,
see (a) below and Diagram 1 on page 3.
2. Remove covers from the wall brackets (b).
3. Position the lower bracket and mark the
wall for the screw fixing (c). Then drill and
plug the wall and fix the lower bracket
without
the rail location notch.
4. Fit the rail into the lower bracket. Place the
remaining bracket
with
the rail location
notch on top of the riser rail, making sure
that the rail slot is located into the notch.
Ensure the hole position is vertically
aligned and mark the wall (d).
Remove the rail and bracket, then drill
and plug the wall.
5. Assemble the height adjuster (e).
6. Compress the height adjuster assembly
and slide onto the rail. Fit the hose
retaining ring and then the soap dish on
the bottom of the rail (f). Lock the soap
dish into position by tightening the lock nut.
7. Replace the rail assembly into the lower
bracket. Refit the top bracket, ensuring the
slot in the rail is located into the bracket
notch and fix to the wall.
Slide covers onto both brackets.
NOTE: The adjustable slider grips the conical nut on the
shower hose (g).
Diagram 5b
Contemporary
White Model
Fitting Instructions
It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use of
abrasive or solvent based cleaning fluid be avoided, especially on any plated finishes.
We recommend that before any cleaning, the isolating switch be turned off, thus avoiding accidentally
switching on the shower.
WARNING: YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR
AND DAMAGE. REPLACE IF NECESSARY, OR EVERY TWO YEARS,
WITH AN APPROVED PART.
WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER,
YOU MUST REGULARLY CLEAN THE SHOWER HANDSET.
All water contains particles of lime-scale, which build up in the shower handset and
unit reducing the performance.
It is therefore important to clean the shower handset by simply rubbing the rubber
nozzles, or soaking in proprietary lime-scale remover and rinsing thoroughly before use.
NOTE:
After use it is normal for some water to drip from the shower handset for a
few moments. This inhibits scale build-up over prolonged use.
9
IF WATER IS TOO COLD
Turn knob “C”
anti-clockwise
to 11 o’clock
and continue turning anti-clockwise until you get
the water temperature of your liking.
Wait 20 seconds
after each adjustment for the
water temperature to stabilise.
The final adjustment may be anywhere on the
dial.
If after turning fully anti-clockwise water is still
too cold, set shower pattern on shower handset to
outer or inner pattern only.
IF WATER IS TOO HOT
Turn
knob “C” clockwise
to 1 o’clock and
continue turning clockwise until you get the water
temperature of your liking.
Wait 20 seconds
after each adjustment for the
water temperature to stabilise.
The final adjustment may be anywhere on the
dial.
If after turning fully clockwise, water is still too
hot, adjust knob “A” to “Medium / ” setting and
re-adjust as above.
Water flow will be reduced on this setting.
1.
Ensure the electricity and water are turned on to the unit.
2.
Your shower has 2 control knobs (see Diagram 6a).
Knob “A” controls the 3 power settings.
The most popular is “High” which is marked “
”.
There are also options for a “Medium” marked “ ”
or “Cold” marked “ ” shower (see notes 7 and 8).
Knob “C” controls the temperature of the water.
For this example turn knob “A” to “High/ ”
and set knob “C” to “12 o’clock”, as shown in
Diagram 6a. The “small bar” indicates knob setting.
3.
Press button “B”
.
The water will flow and the neon indicator will illuminate.
4.
Allow about 20 seconds
for the temperature of the water to stabilise.
It is recommended that you do not wholly enter the water spray during
this period, even if the shower has just been used.
5.
Once a temperature setting to your liking has been achieved, knob “C” will rarely need adjusting.
You must however take into account required adjustments for variations of incoming mains water
temperature between summer and winter (see “Effect of Seasonal Incoming Water Temperature
Changes” see page 13).
6.
When you have
finished
showering,
press button “B”
only.
You have no need to adjust knobs “A or C”.
The water will stop flowing and the neon indicator will go out.
10.5kW Variants Only -
Water will continue to flow for approximately 7 seconds before switching off.
Switch off the electricity at the ceiling switch or local isolator.
7.
The “Medium / ” setting of knob “A” reduces the power used by the shower giving a cooler shower or
the option of reduced water flow.
This option is mainly used for summer usage and if this is used then knob “C” must be re-adjusted.
8.
The “Cold /
” setting of knob “A” will supply water without any heating.
9.
Your shower is
designed to stabilise temperature
changes caused by water pressure fluctuations
(see “Effect of Other Water Devices on Incoming Water Supply” see page 13).
WARNING: DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
WARNING: DO NOT OPERATE THE SHOWER IF WATER IS DISCHARGED FROM THE PRESSURE RELIEF
VALVE. MAINTENANCE IS REQUIRED BEFORE THE SHOWER CAN BE USED.
WARNING: CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY AND THE
INFIRM WHILST THEY USE THIS SHOWER.
HOW TO USE YOUR
AQUAWAVE CONTEMPORARY
SHOWER (DETAILED)
Relates to the
Contemporary
Shower Range ONLY, see unique section for
Heritage
Range