c) ELECTRICAL 

 

WARNING: THIS SHOWER MUST BE EARTHED.  

 

The electrical installation must be in accordance with the current BS.7671 (IEE Wiring Regulations)                  

and “Part P” of the Building Regulations and/or local regulations. 

 

1.

 

The shower unit is designed for a single phase AC electrical supply. 

Please check the rating plate on the unit to see what details apply to your shower.                                        

AS A

 

GUIDE ONLY    (* Only applies if external earth impedance is less than 0.35 Ohms) 

                                                                  

 

Rating 

Cable Sizes 

Fuse / MCB                     

Cable Length 

6.0mm² 

10.0mm² 

40A Type B MCB 

27m Max.  

45m Max.                 

8.5 / 7.8kW  240 / 230V

 

6.0mm² 

10.0mm² 

45A BS.1361 fuse 

12m Max.

*

  

21m Max.

*

   

6.0mm² 

10.0mm² 

40A Type B MCB 

27m Max.  

45m Max.                 

9.5 / 8.7kW  240 / 230V

 

6.0mm² 

10.0mm² 

45A BS.1361 fuse 

12m Max.

*

  

21m Max.

*

   

10.5 / 9.6kW  240 / 230V 

10.0mm² 

45A BS.1361 fuse 

12m Max.

*

 

 

Remember to upgrade the cable if it runs in thermal insulation in a loft, or for a longer distance. 

 

2.

 

A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with 

the wiring rules. We recommend a ceiling switch mounted in a convenient position. 

 

3.

 

If you have decided to connect the cable on the left hand side then please remove and use the                                     

cable clamp that was provided along the right side (see Diagram 3). 

 

WARNING:  IF LEFT HAND SIDE CABLE ENTRY IS USED, THE MAINS CABLE OUTER SHEATH 

MUST BE STRIPPED BACK TO THE LEVEL MARKED ON THE BACKPLATE, AND ALL 

THREE CONDUCTORS MUST BE FULLY SLEEVED WITH THE SLEEVING PROVIDED 

BETWEEN THERE AND THE TERMINAL BLOCK (SEE DIAGRAM 3a).  

 

4.

 

Connect cable to terminal block making sure that all the retaining screws are 

VERY

 

TIGHT

 and that 

no cable insulation is trapped under the screws. 

 

WARNING:  FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN FAILURE 

OF THE TERMINAL BLOCK. 

 

5.

 

Re-fit the detachable bottom section with the two screws if it was removed. 

 

11 

 
 

                                                                                                                         

 

SELF HELP 

 

If the shower is not working satisfactorily, make the following checks before calling out the installer.                                                       
Any one of these adjustments could restore the performance. 

 

The shower cycles 

from HOT to COLD 

The shower temperature is set too hot causing the thermal cut-out (safety 

device) to operate. 

Turn knob “C” clockwise

 

to increase water flow.                                                      

Slowly increase the water temperature by turning knob “C” anti-clockwise until a 

comfortable showering temperature has been reached. 

You MUST WAIT approximately 20 seconds for each adjustment to affect the 

water temperature. 
“Med (medium) /   ” setting may need to be selected. 

Water too HOT 

Increase water flow by adjusting knob “C” clockwise. 
“Med (medium) /   ” setting may need to be selected. 

Increase pressure to water supply e.g. fully open service valve or stop cock.  

Check hose is not kinked restricting the water flow and clean handset. 

Water too COLD 

Check power is on by neon indicator being illuminated. 
Decrease water flow by adjusting knob “C” anti-clockwise.  
“High / 

 

” setting may need to be selected. 

Select inner or outer only handset spray pattern. 

Spray pattern poor  Clean the shower handset. 
Water takes longer 

to heat up 

Thermal cut-out has operated after previous use and the neon indicator has 

gone out (automatically resets when unit cools down) 
“High / 

 

” setting may need to be selected. 

Water goes cold  

while using  

shower 

Check neon indicator is illuminated. 

Check water pressure has not fallen so far as to let pressure switch cut out, 

e.g. Another tap drawing water off.   

Raise position of shower handset. 

Broken parts 

Please contact our spares department on 0870 9000 420 (UK only). 

Fitting instructions are provided with most spares 

Water continues to 

flow when button 

“B” pressed to stop 

This is normal for 10.5kW models only (Other models contact “After Sales”)                                                                                                   

The shower includes a shutdown feature that means the water will continue to 

flow for up to 7 seconds after “  (stop)” has been selected. 

 

 

 

Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person. 

 

White 2.0m Shower Hose 

Cat No. 83792578  

Cover 

Contemporary

 White   

Cat No. 93590348 

Chrome 1.25m Shower Hose  Cat No. 93797641 

Cover 

Contemporary

 Colour   

Cat No. 93590349  

WRAS Listed Water   

 

 

 

Cover 

Heritage

 

 

 

Cat No. 93590350 

Isolating Valve 

 Cat No. 93792452  

Thermal Cut-Out 50/88°C 

 

Cat No. 93597871 

Chrome Standard Accs 

Cat No. 83595317 

Solenoid Valve  

 

 

Cat No. 93590355 

Chrome Multi-Mode Accs 

Cat No. 83595318 

Backplate Lower Section 

 

Cat No. 93590356 

Chrome Curved Accessories  Cat No. 83595320 

PRV Outlet Body Assy  

 

Cat No. 93590357 

Curtain and Rail Pack   

Cat No. 83792812 

Flexible Outlet Pipe c/w Clip   

Cat No. 93590358 

Curtain and Rail Pack with    

 

 

Tank Clip 

 

 

 

Cat No. 93590715 

Non-Slip Mat 

 Cat No. 83792811 

PRV Washer   

 

 

Cat No. 93795817 

Cylinder “O”-Ring 

 

 

Cat No. 93795809 

Handset - 

Contemporary

 

 

Cat No. 93597864 

Height Adjuster - 

Contemporary

 

Cat No. 93597861 

Handset - 

Heritage

   

 

Cat No. 93593571 

Height Adjuster - 

Heritage

 

 

Cat No. 93590361  

WHAT TO DO IF THINGS GO WRONG (1) 

    

ADDITIONAL ACCESSORIES                             COMMON SPARE PARTS     

Additional accessories and spare parts 

can be supplied against any  

Credit or Debit cards from 
Creda Sales Hotline 0870 9000 420 

 

Содержание Aquawave White

Страница 1: ...again The water will stop flowing and the neon indicator will go out 10 5kW Models Only Water will continue to flow for approximately 7 seconds before switching off 6 Switch off the electricity suppl...

Страница 2: ...to have an open outlet and should only be used with Creda recommended fittings 8 Take care to avoid restricting the outlet of the pressure relief device If water is discharged from the pressure relie...

Страница 3: ...be fitted available from us if required 4 Fix the riser rail with screws provided The fixing holes at the base of the brackets will be disclosed by removing the plastic fronts Aquawave Contemporary M...

Страница 4: ...ndset until after the front cover and detachable bottom section are fitted WARNING DO NOT FIT A TAP ON THE SHOWER OUTLET WARNING TAKE CARE TO AVOID RESTRICTING THE OUTLET OF THE PRESSURE RELIEF VALVE...

Страница 5: ...s from pressure relief valve Check for cause of high pressure and remove it Blockage on outlet e g blocked shower handset Replace the pressure relief disc not covered by guarantee Water does not flow...

Страница 6: ...temperature Med medium setting may need to be selected Water too HOT Increase water flow by adjusting knob C clockwise Med medium setting may need to be selected Increase pressure to water supply e g...

Страница 7: ...ption of reduced water flow This option is mainly used for summer usage and if this is used then knob C must be re adjusted 8 The Cold setting of knob A will supply water without any heating 9 Your sh...

Страница 8: ...anywhere on the dial If after turning fully anti clockwise water is still too cold set shower pattern on shower handset to outer or inner pattern only IF WATER IS TOO HOT Turn knob C clockwise to 1 o...

Отзывы: